A stability-indicating LC–MS/MS method for zidovudine: Identification, characterization and toxicity prediction of two major acid degradation products

نویسندگان

  • Prashant S. Devrukhakar
  • M. Shiva Shankar
  • G. Shankar
  • R. Srinivas
چکیده

Zidvovudine (AZT) is a nucleoside analogue reverse transcriptase inhibitor (NRTI), a class of anti-retroviral drug. A stability-indicating assay method for AZT was developed in line with ICH guideline. Successful separation of AZT and its degradation products was achieved by gradient elution mode on reverse phase C18 column using 10 mM ammonium acetate: acetonitrile as the mobile phase at 0.8 mL/min flow rate, 25 µL injection volume, 30 °C column temperature and 285 nm detection wavelength. Two major acid degradation products were identified and characterized by liquid chromatography-electrospray ionization mass spectrometry (LC-ESI/MS/MS) and accurate mass measurements. The probable mechanisms for the formation of degradation products were identified based on a comparison of the fragmentation pattern of the [M + H] + ions of AZT and its degradation products. One of the degradation products, DP-1, was isolated by semi-preparative high performance liquid chromatography (HPLC) using Waters XBridge Prep C18 (250 mm×10 mm, 5 µm). Degradation products showed higher toxicity compared to the drug in some models assessed by TOPKAT software. The method validation was performed with respect to robustness, specificity, linearity, precision and accuracy as per ICH guideline Q2 (R1).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and Validation of a Stability-Indicating RP-UPLC Method for Determination of Rosuvastatin and Related Substances in Pharmaceutical Dosage Form

A stability-indicating reversed phase ultra performance liquid chromatographic (RP-UPLC) method was developed for the determination of related substances in rosuvastatin calcium (ROSV) tablet dosage form. The chromatographic separation was achieved on an Acquity BEH C18 (100 mm × 2.1 mm, 1.7 μm) column with mobile phase containing a gradient mixture of solvent-A (0.1% trifluoroacetic acid) and ...

متن کامل

Forced Degradation Behaviour of Fluphenazine Hydrochloride by LC and Characterization of its Oxidative Degradation Product by LC–MS/MS

A novel, stability-indicating high-performance liquid chromatographic (HPLC) method is delivered for the determination of fluphenazine hydrochloride (FPZ) and its degradation products. The forced degradation testing of FPZ was carried out for hydrolytic, oxidative, photolytic, and thermal degradation. The degradation appeared using a reversed-phase C18 column at ambient temperature with a mobil...

متن کامل

Identification of Forced Degradation Products of Itopride by LC-PDA and LC-MS

Degradation products of itopride formed under different forced conditions have been identified using LC-PDA and LC-MS techniques. Itopride was subjected to forced degradation under the conditions of hydrolysis, photolysis, oxidation, dry and wet heat, in accordance with the International Conference on Harmonization. The stress solutions were chromatographed on reversed phase C18 (250×4.6 mm, 5 ...

متن کامل

A Validated Stability-Indicating LC Method for Fluocinonide in the Presence of Degradation Products, Its Process-Related Impurities and Identification of Degradation Products

The objective of the current study was to develop a validated, specific and stability-indicating reverse phase liquid chromatographic method for the quantitative determination of fluocinonide and its related substances. The determination was done for active pharmaceutical ingredient and its pharmaceutical dosage forms in the presence of degradation products, and its process-related impurities. ...

متن کامل

Identification and Characterization of an Oxidative Degradation Product of Fexofenadine, Development and Validation of a Stability-Indicating RP-UPLC Method for the Estimation of Process Related Impurities and Degradation Products of Fexofenadine in Pharmaceutical Formulations

A novel stability-indicating gradient RP-UPLC method was developed for the quantitative determination of process related impurities and forced degradation products of fexofenadine HCl in pharmaceutical formulations. The method was developed by using Waters Aquity BEH C18 (100 mm x 2.1 mm) 1.7 μm column with mobile phase containing a gradient mixture of solvent A (0.05% triethyl amine, pH adjust...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2017