Correction of partial volume effects in PASL perfusion measurements

نویسندگان

  • M. Pimentel
  • P. Vilela
  • I. Sousa
  • P. Figueiredo
چکیده

Figure 4: Comparison of activation data averaged across subjects with and without PVE correction. Baseline CBF is shown in blue and the amount of CBF change due to activation is shown in red. 3.5 10.4 0 150 Figure 3: Activation Z maps (hot colour scale) superimposed on CBF map (grey scale in ml / 100g / min) from one representative subject. Correction of partial volume effects in PASL perfusion measurements

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

1 Test - Retest Reproducibility of perfusion measurements using PASL at 3 T

Introduction: Pulsed arterial spin labeling (PASL) perfusion imaging of cerebral blood flow (CBF) has already proven to be an useful instrument in studying brain pathologies [1,2]. However, validated quantitative imaging methods are not yet provided by the manufacturers. Therefore, the aim of the current study was to investigate the reproducibility of a PASL imaging sequence based on the previo...

متن کامل

Precision and Accuracy of Arterial Spin Labeling Perfusion MRI in the Pediatric Population

Introduction Arterial Spin Labeling (ASL) provides a noninvasive means for measuring quantitative cerebral blood flow (CBF) without the use of exogenous contrast agents, and is particularly appealing for pediatric populations (1). In neurodevelopmental studies, quantitative CBF can serve as an important marker of cognitive development in normal children as well as aberrant changes in brain func...

متن کامل

Quantitative Mapping of the Age-Dependence of Cerebral Blood Flow using Pulsed Arterial Spin Labeling

Introduction The relationship between aging and cerebral blood flow (CBF) in healthy adults remains a topic of debate [1-3]. Various quantitative perfusion-weighted imaging (PWI) techniques have been employed, including positron-emission tomography (PET) [1] and dynamic susceptibility contrast (DSC) MRI [2]. However, PET and DSC seem to disagree on whether CBF changes at all with age, an issue ...

متن کامل

Partial volume correction incorporating Rb-82 positron range for quantitative myocardial perfusion PET based on systolic-diastolic activity ratios and phantom measurements

BACKGROUND Quantitative myocardial PET perfusion imaging requires partial volume corrections. METHODS Patients underwent ECG-gated, rest-dipyridamole, myocardial perfusion PET using Rb-82 decay corrected in Bq/cc for diastolic, systolic, and combined whole cycle ungated images. Diastolic partial volume correction relative to systole was determined from the systolic/diastolic activity ratio, s...

متن کامل

Effect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis

Introduction: The key characteristics of positron emission tomography (PET) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. Therefore, accurate quantification is important. However, it can be sensitive to several physical factors. The aim of this investigation is the assessment of the e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009