Diagnostic accuracy of haemoglobin colour strip (HCS-HLL), a digital haemoglobinometer (TrueHb) and a non-invasive device (TouchHb) for screening patients with anaemia.
نویسندگان
چکیده
AIM Estimation of haemoglobin (Hb) remains a challenge, particularly in outreach settings. There is a need to have a simple and cost-effective device to detect anaemia. Three devices (haemoglobin colour scale (HCS)-HLL (Hindustan Lifecare Limited), TrueHb V.1.1, TouchHb Alpha 1.1- non-invasive) have been developed in India recently. This study aimed to determine the diagnostic accuracy of these tests (index) for the screening of anaemia against haematological autoanalyzer (reference). METHODS The study was conducted in four medical colleges of India. All consenting adult patients (>18 years of age) undergoing routine investigations were included. Each patient underwent the reference test and at least one index test. Outcome assessors for the index tests were blinded to the results of the reference test. Diagnostic accuracy was calculated using cut-offs proposed by WHO. RESULTS A total of 5244 patients underwent the reference test while HCS-HLL, TrueHb and TouchHb tests were conducted on 2745, 2331 and 2874 patients respectively. The positive likelihood ratio of HCS-HLL using capillary blood (1.2), venous blood (1.7) and TouchHb (1.5) was lower than TrueHb capillary (3.7; 95% CI 3.3 to 4.2) and venous blood (5.7; 95% CI 4.9 to 6.6). TrueHb had a sensitivity of 74.4% (95% CI 71.9% to 76.8%) for venous and 82.0% (95% CI 79.8% to 89.2%) for capillary samples. The specificity was high (>75.0%). The area under receiver operating characteristic was close to 80.0%. Consistent results were seen for detection of severe anaemia. CONCLUSIONS The digital method (TrueHb) emerged as a better diagnostic method for screening anaemia. Its effectiveness should be established in outreach settings before further recommendation.
منابع مشابه
Validity and reliability of haemoglobin colour scale and its comparison with clinical signs in diagnosing anaemia in pregnancy in Ahmedabad, India.
This study compared the validity of the haemoglobin colour scale (HCS) and clinical signs in diagnosing anaemia against Sahli's haemoglobinometer method as the gold standard, and assessed the reliability of HCS. The sample comprised 129 pregnant women recruited from 6 urban health centres in Ahmedabad. The prevalence of anaemia was 69.8% by Sahli's method, 78.3% by HCS and 89.9% by clinical sig...
متن کاملEvaluation of WHO haemoglobin colour scale & palmar pallor for screening of anaemia among children (6-35 months) in rural Wardha, India.
BACKGROUND & OBJECTIVE Anaemia is a public health problem in India, particularly in women and children. Clinical diagnosis by health workers may be inaccurate. It is therefore important to evaluate simple methods for diagnosis of anaemia in rural set up with no or minimal laboratory facilities. We carried out this study to evaluate the performance of haemoglobin colour scale and palmar pallor a...
متن کاملValidation of the haemoglobin colour scale for screening blood donors in Malawi.
BACKGROUND In 2009 Malawi introduced a new protocol to screen potential blood donors for anaemia, using the WHO Haemoglobin Colour Scale (HCS) for initial screening. Published studies of the accuracy of the HCS to screen potential blood donors show varying levels of accuracy and opinion varies whether this is an appropriate screening test. The aim of the study was to assess the validity of the ...
متن کاملCost-effective on-site screening for anaemia in pregnancy in primary care clinics.
OBJECTIVE To determine the feasibility, accuracy and cost of developing a system of on-site screening for anaemia in pregnancy in primary care clinics. SETTING Mobile clinic team in Hlabisa health district, KwaZulu-Natal. METHODS Four hundred and forty-nine consecutive women attending antenatal clinics were screened for anaemia (haemoglobin < 10 g/dl) using copper sulphate solution; the res...
متن کاملAssessing Diagnostic Accuracy of Haemoglobin Colour Scale in Real-life Setting
The study was undertaken to determine diagnostic accuracy of Haemoglobin Colour Scale (HCS) in hands of village-based community health workers (CHWs) in real-life community setting in India. Participants (501 women) were randomly selected from 8 villages belonging to a project area of SEWA-Rural, a voluntary organization located in India. After receiving a brief training, CHWs and a research as...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 69 2 شماره
صفحات -
تاریخ انتشار 2016