Detection of precytopathic effect of enteroviruses in clinical specimens by centrifugation-enhanced antigen detection.

نویسندگان

  • S M Lipson
  • K David
  • F Shaikh
  • L Qian
چکیده

Rapid enterovirus detection is important for decisions about antibiotic administration and length of hospital stay. The efficacy of rapid antigen detection-cell culture amplification (Ag-CCA) was evaluated with monoclonal antibodies (MAbs) 5-D8/1 (DAKO) and Pan-Enterovirus clone 2E11 (Chemicon) with 10 poliovirus, echovirus, and coxsackievirus type A and B stock isolates and College of American Pathologists check samples. By using Ag-CCA technology, MAb 2E11 was more sensitive than 5-D8/1 at detecting a greater number of stock isolates at or past tube (cytopathic effect [CPE]) culture (TC) end points. The efficacy of Ag-CCA in the clinical setting was subsequently confirmed with 273 consecutively freshly collected nasopharyngeal aspirate or swab specimens, rectal swab, and cerebrospinal fluid specimens during the 1999 enterovirus season. All specimens were tested by Ag-CCA in parallel with rhesus monkey kidney (RhMk), MRC-5, and A549 conventional TCs. Approximately 60% of field specimens were additionally tested with Hep-2 and HNK conventional TCs. Sixty-two percent of the clinical specimens tested were Ag-CCA positive after 48 h. Among 51 isolates, the mean time to CPE or culture confirmation was 5.5 days (range, 2 to 18 days). After 48 h, Ag-CCA achieved sensitivity, specificity, and positive and negative predictive values of 62, 100, 100, and 93%, respectively. During the same period, TC-CPE displayed test parameters of 12, 100, 100, and 85%, respectively. After 5 days, the sensitivity and specificity of Ag-CCA increased to 92 and 98%, respectively. Within the same period, isolation attained sensitivity and specificity of 52 and 100%, respectively. Although Ag-CCA displayed slightly reduced sensitivity and reduced specificity compared with conventional cell culture after 14 days, the markedly superior 48-h enterovirus Ag-CCA detection rate supports incorporation of this assay into the routine clinical setting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of enteroviruses in clinical samples of patients with aseptic meningitis by rapid antigen detection assay.

INTRODUCTION Human enteroviruses represent the most common etiological agents of aseptic meningitis. Rapid diagnosis of aseptic meningitis affects the management of patients. OBJECTIVE The aim of this work was to assess the efficacy of rapid antigen detection (RAD) assay for the confirmation of human enteroviruses in comparison to that of the conventional cell culture (CCC), and to identify t...

متن کامل

Comparison of Dot-ELISA with microbial culture for detection of Brucella spp. in clinical specimens

Definitive diagnosis of brucellosis is made by isolation of the causative agents, which is a timeconsumingprocedure. To evaluate the efficacy of Dot-ELISA for detecting brucellae in clinical samples, 94different specimens taken from animal origin were cultured on brucella selective culture media and colonieswere identified biochemically. The specimens were also examined after centrifugation by ...

متن کامل

تشخیص همزمان ویروس‌های انترو و اوریون در نمونه‌های مایع مغزی نخاعی مشکوک به مننژیت توسط تست RT-PCR

  Introduction: Detection of enteroviruses and mumps virus nucleic acid in cerebrospinal spinal fluid (CSF) specimens has been demonstrated to improve the management of patients with aseptic meningitis. Then rapid and sensitive diagnostic techniques are desirable.   Materials & Methods: Multiplex RT-PCR has the potential to detection both of viruses. This assay is so rapid and sensitive. At fir...

متن کامل

OCCURRENCE OF VIRUSES AND P RO TOZOAN PARASI TES IN SURFACE, GROUND AND TREATED WATER IN THE CI TY OF MASHHAD, IRAN

A research plan was developed to evaluate the occurrence of enteroviruses, giardia cysts and cryptosporidium oocysts in thirty-five different sites in the city of Mashhad, Iran. The occurrence of these pathogenic microorganisms was evaluated to investigate a possible health risk in the communities. For the detection of enteroviruses in water samples, the conventional method of cell culture...

متن کامل

Laboratory diagnosis of respiratory virus infections in 24 hours by utilizing shell vial cultures.

Immunofluorescence staining of centrifugation-enhanced shell vial (SV) cultures for respiratory viruses (RV) after 24 h of incubation, rather than the more commonly prescribed times of 48 h and 5 days, allowed for the detection of 77% of the RV-positive specimens that would ordinarily not have been detected as positive until 48 h. Staining SVs at 24 h also permitted earlier detection of viruses...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 39 8  شماره 

صفحات  -

تاریخ انتشار 2001