Measuring the 3D resolution of a micro-focus X-ray CT setup
نویسندگان
چکیده
One of the most important specifications of an industrial X-ray computed-tomography (CT) setup used for inspection is the 3-dimensional (3D) resolution that can be achieved in the volumetric image. Sometimes CT setups are evaluated in this regard using a 2D object such as the JIMA micro resolution chart; however, this approach measures the 2D resolution in a projection image and characterizes the performance of X-ray source and detector, not that of the complete CT setup. Depending on the CT acquisition trajectory, component alignment, and reconstruction artifacts, the 3D resolution might be considerably worse than the 2D resolution. It is therefore desirable to directly measure the 3D resolution. A micro-structured silicon phantom suitable for high-magnification X-ray CT with a microfocus source, and containing structure widths down to one micrometer, has recently been made available by QRM GmbH. The phantom can be used to determine the axial and in-plane 3D resolution in several ways: "by eye" using bar and hole patterns as well as a "Siemens star", using a slanted-edge MTF as per ISO 12233, and by evaluation of the image contrast as a function of structure width. We report on experimental results with the new phantom and on the influence of CT correction methods on the 3D resolution.
منابع مشابه
تشخیص ساختمان داخلی فرش دستباف با استفاده از تصاویر سیتیاسکن میکروفوکوس حاصل از تبدیل رادون معکوس
In addition to medical recognition applications, X-ray CT-scan images are increasingly found to have more innovative and widespread applications. Due to the ability of producing high resolution and high contrast images from soft tissues with low attenuation coefficients, the usage of X-ray micro-focus source, which has a very small focal point (in the range of micrometer), plays an important ro...
متن کاملAdvantages of CT in 3D Scanning of Industrial Parts
Industrial CT (computerized tomography) uses a series of 2-dimensional images taken at specific intervals around the entire sample. Basically any type of industrial CT system uses three principal components: an X-ray tube, an X-ray detector, and a rotational stage. Everything is enclosed within a radiation shielding steel/lead/steel cabinet that typically ranges between four and 10 feet cubed. ...
متن کاملAdvantages of CT in 3D Scanning of Industrial Parts
Industrial CT (computerized tomography) uses a series of 2-dimensional images taken at specific intervals around the entire sample. Basically any type of industrial CT system uses three principal components: an X-ray tube, an X-ray detector, and a rotational stage. Everything is enclosed within a radiation shielding steel/lead/steel cabinet that typically ranges between four and 10 feet cubed. ...
متن کاملThe effect of focal spot size on the spatial resolution of variable resolution X-ray CT scanner
Background: A variable resolution X-ray (VRX) CT scanner provides a great increase in the spatial resolution. In VRX CT scanners, the spatial resolution of the system and its field of view (FOV) can be changed according to the object size. One of the main factors that limit the spatial resolution of VRX CT scanner is the effect of the X-ray focal spot. Materials and Methods: A theoreti...
متن کاملAdvanced Applications of Computed Tomography by Combination of Different Methods
Advanced applications of materials need sophisticated measurement methods for research, process development and quality control. X-ray Computed Tomography (CT) is a very powerful method for non-destructive testing of materials. A CT-scanner generates a series of X-ray attenuation measurements, which are used to produce computed reconstructed images of an object. In the last years 3D-CT systems ...
متن کامل