Effect of the amount of battery charge on tube voltage in different hand-held dental x-ray systems

نویسنده

  • Eun-Kyung Kim
چکیده

PURPOSE Hand-held dental x-ray system is a self contained x-ray machine designed to perform intraoral radiography with one or two hands. The issue about its usage as general dental radiography is still in dispute. The aim of the present study was to assess the relationship between the amount of battery charge and the tube voltage in different hand-held dental x-ray systems. MATERIALS AND METHODS Seven hand-held dental x-ray units were used for the study. Tube voltage was measured with Unfors ThinX RAD (Unfors Instruments AB, Billdal, Sweden) for 3 consecutive exposures at the different amount of battery charge of each unit. The average and the deviation percentage of measured kV from indicated kV of each unit were calculated. RESULTS Tube voltage of only 1 unit was 70 kV (indicated by manufacturer) and those of the others were 60 kV. Tube voltage deviation percentage from the indicated kV at the fully charged battery was from 2.5% to -5.5% and from -0.8% to -10.0% at the lowest charged battery. CONCLUSION Tube voltages of all units decreased as the residual amount of the battery charge decreased. It is suggested that the performance test for hand-held x-ray system should be performed for the minimum residual charged battery as well as the full charged one. Persistent battery charging is suggested to maintain the proper tube voltage of the hand-held portable x-ray system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Experimental and Comparative Analysis of the Battery Charge Controllers in Off-Grid PV Systems

The study of the battery charge process as the only power storage agent in off-grid systems is of significant importance. The battery charge process has different modes, and the battery in these modes is dependent on the amount of charge. In order to charge the battery in off-grid systems, two charge controllers including Pulse Width Modulation (PWM) and Maximum Power Point Tracker (MPPT) are c...

متن کامل

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

Investigating the effect of voltage fluctuations on the beam quality of X-rays in the range energy of diagnostic radiology

The purpose of this study was to investigate the effect of voltage ripple produced by X-ray machines on the quality of X-ray rays. For this purpose, the energy spectrum from the X-ray tube manufacturer should be simulated in the range of diagnostic radiography and verified by experimental results. The statistical analysis of the results showed that there is no significant difference between sim...

متن کامل

An Enumeration Survey on Diagnostic X-Ray Generators and Essential Safety Parameters in Mizoram, India

Introduction: Best radiography practice involves operational optimal machine performance, delivering cost-effective healthcare services under appropriate safety conditions for workers and the public. The present study aimed to investigate the safety status of diagnostic X-ray installations in Mizoram, India. Material and Methods: Lineari...

متن کامل

Synthesis and Characterization of LiMnPO4/Carbon Nanocomposite Material as Cathode Material

Development of an eco-friendly, low cost and high energy density LiMnPO4 cathode material has attracted much attention due to its high operating voltage vs. Li falling within the electrochemical stability window of conventional electrolyte solutions and offers more safety features due to the presence of a strong P-O covalent bond.Synthesis of battery materials integrates the...

متن کامل