Applications of IMAT in cervical esophageal cancer radiotherapy: a comparison with fixed‐field IMRT in dosimetry and implementation
نویسندگان
چکیده
This study aimed to compare fixed-field, intensity-modulated radiotherapy (f-IMRT) with intensity-modulated arc therapy (IMAT) treatment plans in dosimetry and practical application for cervical esophageal carcinoma. For ten cervical esophageal carcinoma cases, f-IMRT plan (seven fixed-fields) and two IMAT plans, namely RA (coplanar 360° arcs) and RAx (coplanar 360° arcs without sectors from 80° to 110°, and 250° to 280°), were generated. DVHs were adopted for the statistics of above parameters, as well as conformal index (CI), homogeneity index (HI), dose-volumetric parameters of normal tissues, total accelerator output MUs and total treatment time. There were differences between RAx and f-IMRT, as well as RA in PTV parameters such as HI, V(95%) and V(110%), but not in CI. RAx reduced lung V₅ from (50.9% ± 9.8% in f-IMRT and (51.4% ± 10.8% in RA to (49.3% ± 10.4% in RAx (p < 0.05). However, lung V₃₀, V₄₀, V₅₀ and MLD increased in RAx. There was no difference in the mean heart dose in three plans. Total MU was reduced from 1174.8 ± 144.6 in f-IMRT to 803.8 ± 122.2 in RA and 736.2 ± 186.9 in RAx (p < 0.05). Compared with f-IMRT, IMAT reduced low dose volumes of lung and total MU on the basis of meeting clinical requirements.
منابع مشابه
Comparison between field-in-field technique and the use of conventional wedges for treatment planning of esophageal cancer
Introduction: This study was conducted to evaluate and quantify the treatment planning performance of MLC-optimized field-in-field planning technique (FIF), also named forward IMRT, versus wedge-based three field (W3F) technique in terms of dosimetric and radiobiological parameters for esophageal carcinoma. Material and Methods: Twenty patients with esophag...
متن کاملOut-Of-Field Dose Measurement and Second Cancer-Risk Estimation Following External Beam Radiotherapy and Brachytherapy for Cervical Cancer Treatment: A Phantom Study
Introduction: The present study aimed to measure the scatter and leakage dose received by out-of-field organs while delivering Radiotherapy (RT) treatment of cervical cancer. Moreover, this study estimated the risk of second cancer (SC). The doses to out-of-field organs were measured using a lithium fluoride (TLD 100) dosimeter while delivering External Beam Radiothera...
متن کاملRectal and Bladder Dose Measurements in the Intracavitary Applications of Cervical Cancer Treatment with HDR Afterloading System: Comparison of TPS Data with MOSFET Detector
Background: Intracavitary brachytherapy plays a major role in management of cervical carcinoma. Assessment of dose received by OAR’s therefore becomes crucial for the estimation of radiation toxicities in HDR brachytherapy. Objective: Purpose of this study is to evaluate the role of in vivo dosimetry in HDR brachytherapy and to compare actual doses delivered to OAR’ s with those calculate...
متن کاملDosimetry evaluation of salivary glands in 3D conformal radiotherapy and intensity modulated radiotherapy in oral tongue cancer
Introduction: The purpose of this study was to evaluate the dosimetric and radiobiological parameters of salivary glands in treatment of patients with oral tongue cancer by 3D conventional radiotherapy (3D-CRT) and intensity modulated radiation therapy (IMRT) techniques. Materials and Methods: This study was performed on treatment planning of patients with oral tongue cancer in T2-3/N0 cancer s...
متن کاملImprovements on the Planning and Delivery of Intensity-Modulated Arc Therapy
In the past decade, intensity-modulated radiation therapy (IMRT) has taken a significant step towards dose conformality and has now become a standard radiotherapy technique in the clinic. In this era, a rotational IMRT technique called intensity-modulated arc therapy (IMAT) was also proposed to possibly further reduce normal tissue toxicity and compete with conventional IMRT. However, clinical ...
متن کامل