Characterization of CsI photocathodes for use in a fast RICH detector
نویسنده
چکیده
We have completed a series of measurements that provide a basic understanding of the properties of CsI photocathodes for use in ring imaging Cherenkov (RICH) detectors. The quantum efficiency of CsI has been measured relative to an NIST-calibrated photodiode and is in excellent agreement with a similar measurement by Breskin et al. A representative value of the quantum efficiency is 20% at 180 nm. The quantum efficiency of a fresh photocathode is unaffected by temperature, but heating the photocathode can be helpful if it has been exposed to water vapor, or has been aged by a large integrated photocurrent. Detailed studies of aging show a “fast” component that appears to be associated with a rise in the work function, and a “slow” component associated with conversion of the bulk CsI to Cs. We judge that a practical lifetime of a CsI photocathode is until it has lost 20% of its initial quantum efficiency, which process is dominated by the “fast” rise in the work function. This rise occurs both due to photoelectron transport with an effective lifetime of 0.1 kc/mm’ and due to positive-ion bombardment with an effective lifetime of 15 &/mm’. When the CsI photocathode is used in a chamber with gas gain greater than 150 the latter lifetime is the relevant one. This lifetime should be sufficient for use of a RICH detector at an e+eB factory. The reduction of quantum efficiency of a CsI photocathode in a gas-filled chamber has been studied for several gases over a wide range of reduced electric field. This effect can be minimized by use of atmospheric-pressure methane in a chamber with anode wires rather than a mesh. We have also demonstrated that excellent spatial resolution for the location of the photoelectrons can be obtained using a coarse cathode-pad readout if the anode-cathode spacing is similar to the pad width.
منابع مشابه
EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH European Laboratory for Particle Physics Aging of large area CsI photocathodes for the ALICE HMPID prototypes
The ALICE HMPID RICH detector is equipped with CsI photocathodes in a MWPC for the detection of Cherenkov photons. The long term operational experience with large area CsI photocathodes will be described. The RICH prototypes have shown a very high stability of operation and performance, at a gain of 10 and with rates up to 2x10 cm s. When exposure to air has been avoided, no degradation of the ...
متن کاملTesting of CsI Photocathodes Efficiencies in a Liquid Xenon Chamber
A summary of the Dark Matter problem and a more detailed overview of the WIMP/neutralino direct detection are introduced. More specifically the XENON – a next generation direct detection detector of WIMPs – is described. A detailed description is given on the techniques used in the current experiment to produce CsI photocathodes. Furthermore the tests done to check the performance of the CsI ph...
متن کاملProduction technique and quality evaluation of CsI photocathodes for the ALICE/HMPID detector
The ALICE/HMPID detector has been equipped with 42 large area CsI photocathodes providing a total of 11m of photosensitive area for the detection of Cherenkov light. This production summary reports on the CsI coating procedure and provides results of the quality monitoring measurements by means of a photocurrent scanner system. The importance of the heat enhancement of CsI PCs is stressed and d...
متن کاملStudy of the quantum efficiency of CsI photo-cathodes exposed to oxygen and water vapour
The operation of CsI photocathodes in gaseous detectors requires special attention to the purity of the applied gas mixtures. We have studied the influence of oxygen and water vapour contaminations on the performance of CsI photocathodes for the ALICE HMPID RICH prototype. Measurements were done through comparison of Cherenkov rings obtained from beam tests. Increased levels of oxygen and water...
متن کاملQuantum efficiency and stability of alkali halide UV photocathodes in the presence of electric field
It was shown previously that CsI sensitivity can be substantially reduced by intense UV irradiation. In the present study we measure the influence of negative and positive electric fields on the degradation of CsI photocathode sensitivity when it is subject to a large dose UV irradiation. The UV sensitivity of positively biased CsI photocathodes did not decay as fast as in case of negatively bi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -