Diffusion MRI tractography of the human heart In Vivo at end-diastole and end-systole

نویسندگان

  • Choukri Mekkaoui
  • Sonia Nielles-Vallespin
  • Peter D Gatehouse
  • Marcel P Jackowski
  • David N Firmin
  • David E Sosnovik
چکیده

Diffusion Tensor MRI (DTI) of the human heart in vivo has to date been performed in 2D and at a single phase of the cardiac cycle. Here we perform 3D tractography of the human heart in vivo at both end diastole and end systole. We show that fiber orientation in the subepicardium becomes more oblique during systole, and that scalar indices of diffusion (mean diffusivity and fractional anisotropy) decrease during systole. Our data suggest that myocardial fiber architecture is dynamic and is a function of both chamber geometry and myocardial contraction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo fiber tractography of the right and left ventricles using diffusion tensor MRI of the entire human heart

Background Diffusion Tensor MRI (DTI) tractography of the human heart in vivo has previously been performed with either large slice gaps or limited coverage [1,2]. The aim of this study was to investigate the feasibility of performing DTI of the entire human heart in vivo without slice gaps. This, we hypothesized, would enhance the characterization of fiber architecture in the left ventricle (L...

متن کامل

DT-MRI Tractography and its Application in Cognitive Neuroscience

Recent advancement of MRI techniques and development of new methods of image analysis have allowed us to study large neural tracts within the human brain. This is based on the principle of diffusion tensor MRI that is similar to that of diffusion-weighted imaging but takes magnitude and direction of the diffusion of water into account. Using this technique we have been able to define large neur...

متن کامل

DT-MRI Tractography and its Application in Cognitive Neuroscience

Recent advancement of MRI techniques and development of new methods of image analysis have allowed us to study large neural tracts within the human brain. This is based on the principle of diffusion tensor MRI that is similar to that of diffusion-weighted imaging but takes magnitude and direction of the diffusion of water into account. Using this technique we have been able to define large neur...

متن کامل

Evaluation of myocardial volume heterogeneity during end-diastole and end-systole using cine MRI.

The aim of this study was to examine the difference in the myocardial volume between end-diastole and end-systole in 24 human volunteers, using steady-state free precession gradient-echo cine imaging of both long- and short-axis views of the left ventricle and a newly developed three-dimensional (3D) analysis method. In addition, we examined retrospectively the cine magnetic resonance imaging (...

متن کامل

Quantification of myocardial blood flow with cardiovascular magnetic resonance throughout the cardiac cycle

BACKGROUND Myocardial blood flow (MBF) varies throughout the cardiac cycle in response to phasic changes in myocardial tension. The aim of this study was to determine if quantitative myocardial perfusion imaging with cardiovascular magnetic resonance (CMR) can accurately track physiological variations in MBF throughout the cardiac cycle. METHODS 30 healthy volunteers underwent a single stress...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2012