Balloon test occlusion of the internal carotid artery: change in stump pressure over 15 minutes and its correlation with xenon CT cerebral blood flow.
نویسندگان
چکیده
PURPOSE To determine whether stump pressure changes significantly over time during temporary internal carotid artery (ICA) occlusion via an endovascular balloon, and to examine correlations between stump pressure changes and cerebral blood flow (CBF) as measured by xenon CT. METHODS Seventy candidates for ICA sacrifice were evaluated preoperatively with a test occlusion of the cervical ICA using an endovascular balloon. Measurements of ICA stump pressure above the occlusive balloon through a distal lumen in the balloon catheter were made throughout the 15-minute test. During occlusion, CBF was measured with stable xenon CT techniques. Patients were then categorized according to CBF results. RESULTS The stump pressure changed significantly (P < .001) during the occlusive period. On average, stump pressure increased 7.7 mmHg (12%). Patients determined by xenon CT to have an asymmetric decrease in CBF with balloon occlusion did not display the upward trend in stump pressures and were significantly different (P = .013) in that respect from patients who demonstrated either no CBF change or only minimal bilaterally symmetric decreases in CBF. CONCLUSIONS Large overlaps among the groups prohibit the use of stump pressure changes as an accurate predictor of CBF or of stroke risk in an individual patient. However, these data suggest an autoregulatory mechanism in the cerebral circulation that evolves over a period of minutes in contrast to the traditional concept of cerebral autoregulation which is thought to occur in a matter of seconds.
منابع مشابه
Comparison of technetium Tc 99m hexamethylpropyleneamine oxime single-photon emission tomograph with stump pressure during the balloon occlusion test of the internal carotid artery.
BACKGROUND AND PURPOSE Measuring blood pressure (stump pressure) in the distal internal carotid artery during occlusion of the internal carotid artery is reportedly a reliable safety index with which to predict ischemia following permanent occlusion of the internal carotid artery. We compared the stump pressure during occlusion of the internal carotid artery with single-photon emission CT (SPEC...
متن کاملStroke risk after abrupt internal carotid artery sacrifice: accuracy of preoperative assessment with balloon test occlusion and stable xenon-enhanced CT.
PURPOSE To evaluate stable xenon-enhanced CT cerebral blood flow with balloon test occlusion as a predictor of stroke risk in internal carotid artery sacrifice. METHODS Abrupt internal carotid artery occlusion was performed by surgical or endovascular means below the origin of the ophthalmic artery in 31 normotensive patients who were assessed preoperatively by a 15-minute clinical balloon te...
متن کاملA Lumped Parameter Method to Calculate the Effect of Internal Carotid Artery Occlusion on Anterior Cerebral Artery Pressure Waveform
Background and Objective: Numerical modeling of biological structures would be very helpful tool to analyze hundreds of human body phenomena and also diseases diagnosis. One physiologic phenomenon is blood circulatory system and heart hemodynamic performance that can be simulated by utilizing lumped method. In this study, we can predict hemodynamic behavior of one artery of circulatory system (...
متن کاملBalloon test occlusion of the internal carotid artery with stable xenon/CT cerebral blood flow imaging.
We describe a technique to predict preoperatively the safety of permanently occluding an internal carotid artery. The method was performed by imaging stable xenon cerebral blood flow (CBF) with the internal carotid artery both open and temporarily occluded with a nondetachable balloon on a double lumen Swan-Ganz catheter. Patients were those in whom we planned to sacrifice the internal carotid ...
متن کاملCerebral blood flow response pattern during balloon test occlusion of the internal carotid artery.
PURPOSE To evaluate the risk of temporary or permanent internal carotid artery occlusion. METHODS In 156 patients intraarterial balloon test occlusion in combination with a stable xenon-enhanced CT cerebral blood flow study was performed before radiologic or surgical treatment. All 156 patients passed the clinical balloon test occlusion and underwent a xenon study in combination with a second...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 14 3 شماره
صفحات -
تاریخ انتشار 1993