Detection of illicit drugs on surfaces using direct analysis in real time (DART) time-of-flight mass spectrometry.

نویسندگان

  • Andrew H Grange
  • G Wayne Sovocool
چکیده

Methamphetamine (meth) from meth syntheses or habitual meth smoking deposited on household surfaces poses human health hazards. The U.S. State Departments of Health require decontamination of sites where meth was synthesized (meth labs) before they are sold. National Institute for Occupational Safety and Health (NIOSH) methods for meth analysis require wipe sampling, extraction, clean-up, solvent exchange, derivatization, and/or mass spectral analysis using selected ion monitoring. Rapid and inexpensive analyses could screen for drug-contamination within structures with greater spatial resolution, provide real-time analyses during decontamination, and provide thorough documentation of successful clean ups. Herein an autosampler/open-air ion source time-of-flight mass spectrometric technique is described that required only direct sampling using cotton-swab wipes. Each wipe sample collection required 2 min and data acquisition required only 13 s per sample. Optimum collision-induced dissociation voltages, desorption gas temperatures, and wipe sample solvents were determined for 11 drugs. Peaks were observed in analyte-ion traces for 0.025 µg/100 cm(2) of meth and seven other drugs. This level is half the detection limit of NIOSH methods and one-fourth of the lowest U.S. state decontamination limit for meth. Dynamic ranges of 100 in concentration were demonstrated for eight drugs, which is sufficient for a screening technique. The volatilities of 11 drugs deposited on glass were determined. The pick up of the drugs by solvent-soaked cotton-swab wipes from glass relative to acrylic latex paint was also compared.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid screening for synthetic antidiabetic drug adulteration in herbal dietary supplements using direct analysis in real time mass spectrometry.

Adulteration of herbal supplements with synthetic drugs is illegal. A rapid and reliable method which utilizes direct analysis in real time mass spectrometry (DART-MS) was developed for the identification of seven synthetic antidiabetic drugs used as adulterants in herbal dietary supplements. The supplement sample was simply extracted with methanol/water by manually shaking several times and di...

متن کامل

QSRR models of veterinary drugs in milk in ultra-performance liquid chromatography coupled to time of flight mass spectrometry

The veterinary drugs residues are also important pollutants found in milk, since veterinary drugs are commonly used in cattle management. Considering the role of milk in human nutrition and its wide consumption throughout the world, it is very important to ensure the milk quality. A quantitative structure–retention relationship (QSRR) was developed using the partial least square (PLS), Kernel P...

متن کامل

Use of proton transfer reaction time-of-flight mass spectrometry for the analytical detection of illicit and controlled prescription drugs at room temperature via direct headspace sampling.

The first reported use of proton transfer reaction time-of-flight mass spectrometry (PTR-TOF-MS) for the detection of a range of illicit and prescribed drugs is presented here. We describe the capabilities of PTR-TOF-MS to detect the following commonly used narcotics-ecstasy (N-methyl-3,4-methylenedioxyamphetamine), morphine, codeine, cocaine and heroin-by the direct sampling of the headspace a...

متن کامل

Rapid direct analysis in real time (DART) mass spectrometric detection of juvenile hormone III and its terpene precursors.

Direct analysis in real time (DART) is a plasma-based ambient ionization technique that enables rapid ionization of small molecules with high sample throughput. In this work, DART was coupled to an orthogonal (oa) time-of-flight (TOF) mass spectrometer and the system was optimized for analyzing a vital hormonal regulator in insects, juvenile hormone (JH) III and its terpene precursors, namely, ...

متن کامل

Versatile new ion source for the analysis of materials in open air under ambient conditions.

A new ion source has been developed for rapid, noncontact analysis of materials at ambient pressure and at ground potential. The new source, termed DART (for "Direct Analysis in Real Time"), is based on the reactions of electronic or vibronic excited-state species with reagent molecules and polar or nonpolar analytes. DART has been installed on a high-resolution time-of-flight mass spectrometer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Rapid communications in mass spectrometry : RCM

دوره 25 9  شماره 

صفحات  -

تاریخ انتشار 2011