Unusual presentation of failed metal-on-metal total hip arthroplasty with features of neoplastic process
نویسندگان
چکیده
Metal-on-metal (MoM) total hip arthroplasty (THA) is associated with increased incidence of failure from metallosis, adverse tissue reactions, and the formation of pseudotumors. This case highlights a 53-year-old female with an enlarging painful thigh mass 12 years status post MoM THA. Radiographs and advanced imaging revealed an atypical mass with cortical bone destruction and spiculation, concerning for periprosthetic malignancy. Open frozen section biopsy was performed before undergoing revision THA in a single episode of care. This case illustrates that massive pseudotumors can be locally aggressive causing significant femoral bone destruction and may mimic malignancy. It is important that orthopaedic surgeons, radiologists and pathologists understand the relative infrequency of periprosthetic malignancy in MoM THA to mitigate patient concerns, misdiagnosis, and allow for an evidence based discussion when treating massive pseudotumors.
منابع مشابه
Cobalt toxicity after revision to a metal-on-polyethylene total hip arthroplasty for fracture of ceramic acetabular component
Cobalt metallosis after revision metal-on-polyethylene total hip arthroplasty for catastrophic failure of ceramic components is uncommon but a potentially devastating complication. Common findings associated with heavy metal toxicity include cardiomyopathy, hypothyroidism, skin rashes, visual disturbances, hearing changes, polycythemia, weakness, fatigue, cognitive deterioration, and neuropathy...
متن کاملFatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature
Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...
متن کاملMetal in Total Hip Arthroplasty: Wear Particles, Biology, and Diagnosis.
Total hip arthroplasty (THA) has been performed for nearly 50 years. Between 2006 and 2012, more than 600,000 metal-on-metal THA procedures were performed in the United States. This article reviews the production of metal wear debris in a metal-on-metal articulation and the interaction of cobalt and chromium ions that ultimately led to a dramatic decline in the use of metal-on-metal THA articul...
متن کاملThe clinical performance of metal-on-metal as an articulation surface in total hip replacement.
The metal-on-metal articulations in total hip arthroplasty (THA) were widely used between 1960 and 1975. The McKee-Farrar and other first-generation prostheses failed at a high rate because impingement caused early component loosening. The problem of early component loosening was corrected by improved component design and better manufacturing quality. Second-generation metal-on-metal total hip ...
متن کاملNeurofibromatosis induced hip arthritis. An unusual presentation
PATIENT Male, 43 FINAL DIAGNOSIS: Neurofibromatosis Symptoms: Hip pain Medication: - Clinical Procedure: - Specialty: Orthopedics and Traumatology. OBJECTIVE Rare disease. BACKGROUND Neurofibromatosis type 1 is a disease known for orthopedic manifestations such as spine deformities, congenital pseudarthrosis of the tibia and other bony dysplasias; joint dislocations are rare. Joint arthriti...
متن کامل