Comparison of BACTEC 9240 Peds Plus medium and isolator 1.5 microbial tube for detection of Brucella melitensis from blood cultures.

نویسندگان

  • P Yagupsky
  • N Peled
  • J Press
  • O Abramson
  • M Abu-Rashid
چکیده

The sensitivity and time to detection of Brucella melitensis by the BACTEC 9240 and the Isolator blood culture systems were compared in a prospective volume-controlled study. Blood sample aliquots, obtained from children with suspected brucellosis, were inoculated into a BACTEC 9240 Peds Plus bottle and into an Isolator 1.5 Microbial Tube. Overall, 122 pairs of blood samples for culture were obtained, and 28 (23%) were positive by at least one method. The BACTEC 9240 system detected all 28 positive cultures (sensitivity, 100%), and the Isolator system detected 22 positive cultures (sensitivity, 79%) (P = 0.023). Among those 22 cultures positive by both methods, 21 (95%) and 15 (68%) were found to be positive within 3 days by the BACTEC and the Isolator systems, respectively; 8 (36%) were found to be positive at least 1 day earlier by the BACTEC instrument, and the remaining 14 were found to be positive by the two systems on the same day (P = 0.045). The BACTEC 9240 blood culture system is more sensitive than the Isolator system for the detection of B. melitensis and is superior in terms of time to detection of the organism.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical comparison of the Isolator 1.5 microbial tube and the BACTEC radiometric system for detection of bacteremia in children.

The Isolator 1.5 microbial tube (E. I. du Pont de Nemours & Co., Inc., Wilmington , Del.) was compared with the BACTEC radiometric detection system (Johnston Laboratories, Inc., Cockeysville, Md.) for the detection of bacteremia in children. The Isolator 1.5 is a blood culture system designed for small volumes of blood (0.5 to 1.5 ml). The method involves lysis of the cells of the patient and t...

متن کامل

Use of the Isolator 1.5 microbial tube for detection of Brucella melitensis in synovial fluid.

Isolation of brucellae from blood and other normally sterile body fluids or tissues remains the only irrefutable evidence for the disease, but detection of the organism in clinical specimens is frequently hampered by the low sensitivity of routine culture methods. Because brucellae have the ability to survive and multiply within phagocytic cells, we speculated that phagocytosis of the organism ...

متن کامل

Clinical comparison of BACTEC 9240 plus aerobic/F resin bottles and the isolator aerobic culture system for detection of bloodstream infections.

The Plus Aerobic/F resin bottle of the BACTEC 9240 automated blood culture system (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) was compared with aerobic culture of the Isolator system (Wampole Laboratories, Cranbury, N.J.) for the detection of bloodstream microorganisms from 6,145 blood cultures collected from adult patients with suspected septicemia. The BACTEC resin bottles w...

متن کامل

Multicenter comparison of BACTEC 9050 and BACTEC 9240 blood culture systems.

The overall recovery of organisms and time to detection with the BACTEC 9050 and BACTEC 9240 systems were compared in a multicenter evaluation. In the first phase of the study, a total of 4,383 compliant aerobic (Plus Aerobic/F) blood culture sets were processed. There was no significant difference in the recovery of individual groups of organisms with the two systems, with the exception of Str...

متن کامل

Prevalence of the Most Common Virulence-Associated Genes among Brucella Melitensis Isolates from Human Blood Cultures in Hamadan Province, West of Iran

Brucellosis is a widespread zoonotic disease causing considerable economic and public health problems. Despite animal vaccination, brucellosis remains endemic in some areas such as Iran, especially in the western Iranian province of Hamadan. We sought to detect some of the most common virulence-associated genes in Brucella isolated from human blood cultures to determine the prevalence of some v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 35 6  شماره 

صفحات  -