B-Mode Ultrasound Image Simulation in Deformable 3-D Medium

نویسندگان

  • Orcun Goksel
  • Septimiu E. Salcudean
چکیده

This paper presents an algorithm for fast image synthesis inside deformed volumes. Given the node displacements of a mesh and a reference 3-D image dataset of a predeformed volume, the method first maps the image pixels that need to be synthesized from the deformed configuration to the nominal predeformed configuration, where the pixel intensities are obtained easily through interpolation in the regular-grid structure of the reference voxel volume. This mapping requires the identification of the mesh element enclosing each pixel for every image frame. To accelerate this point location operation, a fast method of projecting the deformed mesh on image pixels is introduced in this paper. The method presented was implemented for ultrasound B-mode image simulation of a synthetic tissue phantom. The phantom deformation as a result of ultrasound probe motion was modeled using the finite element method. Experimental images of the phantom under deformation were then compared with the corresponding synthesized images using sum of squared differences and mutual information metrics. Both this quantitative comparison and a qualitative assessment show that realistic images can be synthesized using the proposed technique. An ultrasound examination system was also implemented to demonstrate that real-time image synthesis with the proposed technique can be successfully integrated into a haptic simulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

I-48: Ultrasound Deformable Model for Virtual Surgery Simulation of Oocyte Retrieval in Infertility Programs

Background The use of a medical simulator should enhance the goals of minimally invasive surgery: patient safety, cosmesis, shortening the length of hospital admissions, and reducing cost. Using an innovative approach to the handling of ultrasound images in virtual reality simulation, this article describes a process that employs a hybrid model of deformable models that can be applied in the te...

متن کامل

O-39: Ultrasound Deformable Model for Virtual Surgery Simulation of Oocyte Retrieval in Infertility Programs

Background The use of a medical simulator should enhance the goals of minimally invasive surgery: patient safety, cosmesis, shortening the length of hospital admissions, and reducing cost. Using an innovative approach to the handling of ultrasound images in virtual reality simulation, this article describes a process that employs a hybrid model of deformable models that can be applied in the te...

متن کامل

Simulation of Patient-Specific Deformable Ultrasound Imaging in Real Time

Intraoperative ultrasound is an imaging modality frequently used to provide delineation of tissue boundaries. This paper proposes a simulation platform that enables rehearsal of patient-specific deformable ultrasound scanning in real-time, using preoperative CT as the data source. The simulation platform was implemented within the GPUaccelerated NVIDIA FleX position-based dynamics framework. Th...

متن کامل

Automated segmentation method for the 3-D ultrasound carotid image based on the Geometrically deformable model with automatic merge function

Stenosis of the carotid is the most common cause of the stroke. The accurate measurement of the volume of the carotid and visualization of its shape are helpful in improving diagnosis and minimizing the variability of assessment of the carotid disease. Due to the complex anatomic structure of the carotid, it is mandatory to define the initial contours in every slice, which is very difficult and...

متن کامل

Prospective-triggered high-pitch spiral versus sequential dual-source CT coronary angiography: comparison of image quality and radiation dose

Background: Prospectively electrocardiography (ECG)-triggered high-pitch spiral coronary computed tomography angiography (CCTA) is a unique scan mode for dual-source CT (DSCT). Our reports aim to compare image quality and radiation dose of CCTA using high-pitch spiral or sequential acquisition mode in patients with low and stable heart rates. Materials and Methods: Patients with low and stable ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • IEEE transactions on medical imaging

دوره 28 11  شماره 

صفحات  -

تاریخ انتشار 2009