Short- and long-term biological variation in cardiac troponin I measured with a high-sensitivity assay: implications for clinical practice.

نویسندگان

  • Alan H B Wu
  • Quynh Anh Lu
  • John Todd
  • Joachim Moecks
  • Frank Wians
چکیده

BACKGROUND The improved detection limit and precision in new-generation commercial assays for cardiac troponin I (cTnI) have lowered the 99th-percentile cutoff value, yielding higher frequencies of positive test results. Because serial testing is important in interpreting low concentrations, we evaluated the biological variation of cTnI in both the short (hours) and long (weeks) terms and determined reference change values (RCVs) and the index of individuality (II) for cTnI. METHODS To assess short- and long-term variation, we collected blood from 12 healthy volunteers hourly for 4 h and from 17 healthy individuals once every other week for 8 weeks, measured cTnI with a high-sensitivity assay (detection limit, 0.2 ng/L), and computed analytical, intraindividual, interindividual, and total CVs (CV(A), CV(I), CV(G), and CV(T), respectively; CV(T) = CV(A) + CV(I) + CV(G)) as well as the II. Because of the slight right-skewness of the data, RCVs were calculated with a lognormal approach. RESULTS Within-day CV(A), CV(I), and CV(G) values were 8.3%, 9.7%, and 57%, respectively; the corresponding between-day values were 15%, 14%, and 63%. Within- and between-day IIs were 0.21 and 0.39, respectively. Lognormal within-day RCVs were 46% and -32%, respectively; the corresponding between-day values were 81% and -45%. CONCLUSIONS The low II indicates that population-based reference intervals are less useful for interpreting cTnI values than following serial changes in values in individual patients. This criterion is particularly important for interpreting results from patients who show cTnI increases at low concentrations measured with very high-sensitivity assays, from patients presenting with chest pain (short term), and for evaluating drugs for cardiotoxicity (long term).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Short- and Long-Term Biological Variation in Cardiac Troponin I with a High-Sensitivity Assay: Implications for Clinical Practice

BACKGROUND: The improved detection limit and precision in new-generation commercial assays for cardiac troponin I (cTnI) have lowered the 99th-percentile cutoff value, yielding higher frequencies of positive test results. Because serial testing is important in interpreting low concentrations, we evaluated the biological variation of cTnI in both the short (hours) and long (weeks) terms and dete...

متن کامل

Biological and analytical variability of a novel high-sensitivity cardiac troponin T assay.

BACKGROUND High-sensitivity cardiac troponin assays will augment the frequency of increased results, making important the determination of reference change values to distinguish acute from chronic increases. We assessed short- and long-term biological variability of cardiac troponin T (cTnT) in healthy subjects with a novel high-sensitivity (hs) assay. METHODS We collected blood from 20 healt...

متن کامل

Short- and long-term individual variation in cardiac troponin in patients with stable coronary artery disease.

BACKGROUND A rise or fall of cardiac troponin is a prerequisite for the diagnosis of acute myocardial infarction. Defining significant changes requires knowledge of both biological and analytical variation. The short-term biological variation of cardiac troponin in healthy individuals is 3%-48%. However, healthy individuals may not be representative for patients in whom cardiac troponin measure...

متن کامل

Biologic variation of a novel cardiac troponin I assay.

Cardiac troponin is the marker of choice for evaluating myocardial injury (1 ). High-sensitivity assays improve analytical detection limits, thereby allowing concentrations to be measured in the majority of healthy individuals. This capability allows an assessment of biologic variation (BV) to determine what constitutes an important change in the cardiac troponin concentration, a critical metri...

متن کامل

Variation of cardiac troponin I and T measured with sensitive assays in emergency department patients with noncardiac chest pain.

BACKGROUND New-generation high-sensitivity assays for cardiac troponin have lower detection limits and less imprecision than earlier assays. Reference 99th-percentile cutoff values for these new assays are also lower, leading to higher frequencies of positive test results. When cardiac troponin concentrations are minimally increased, serial testing allows discrimination of myocardial infarction...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 55 1  شماره 

صفحات  -

تاریخ انتشار 2009