Shortened Quarter Lambda antenna for traveling wave excitation in high field MRI

نویسندگان

  • H. Kroeze
  • A. Andreychenko
  • C. A. van den Berg
  • D. W. Klomp
  • P. R. Luijten
چکیده

Introduction Recently the concept of traveling wave excitation was demonstrated for high field MRI (1). In these experiments RF excitation and reception was done by using a patch antenna, suited for this task. The disadvantage of this antenna, however, is its size. A proper patch antenna for 7 T MRI is almost as large as the diameter of the bore. This limits the location of the antenna to the edge of the bore, relatively far from anatomical structures to be imaged in, for instance, the abdominal area. In the latter case, tissue between the object to be imaged and the actual antenna will act as an attenuator, reducing image quality and SN ratio. Moreover, a large patch antenna will block any access to the patient at the backend of the magnet, which may jeopardize access to visual stimuli as well. We therefore propose the use of a mechanically less constrained Shortened Quarter Lambda (SQL) antenna for setting up travelling waves, and demonstrate 8 fold improved efficiency in the abdomen compared to a patch antenna Methods A quarter lambda antenna mounted on a ground plane is a good and efficient radiator (2). At 298.2 MHz such an antenna has a length of 250 mm. To further reduce the length of the antenna, an inductor is introduced at the base of the antenna. The inductor consists of 3 turns of the antenna wire (1.8 mm) with an inner diameter of 12 mm. A groundplane of 160*360 mm was employed. By varying the length of the antenna wire and the length of the inductor, the SQL antenna can easily by tuned and matched. To enable quadrature excitation, two SQL antennas were placed on a 90 folded groundplane (figure 1). To compare the performance of the SQL antenna to a circular quadrature patch antenna, FFE images were obtained from a cylindrical phantom and a healthy male volunteer with both antennas at equal RF power settings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Human Brain Imaging at 9.4 Tesla Using a Combination of Traveling Wave Excitation with a 15-channel Receive-only Array

Introduction The combination of a circularly polarized (CP) volume coil for spin excitation with a multi-channel receive-only array is a successful setup for routine human brain imaging at 7 Tesla. For reception, the use of multiple surface coils is important for a high SNR and for the utilization of parallel imaging techniques. For transmission, the main strength of the CP coil is the reasonab...

متن کامل

Effective delivery of the traveling wave to distant locations in the body at 7T

Introduction The possibility of application of the traveling wave concept for MRI experiments on a whole body at ultra high fields was recently confirmed by the experiments in Zürich and Utrecht [1, 2]. In these experiments excitation and reception is carried out by a single antenna situated at the beginning of the cavity of a 7 Tesla MR scanner which guides traveling waves along its longitudin...

متن کامل

Mid-Bore Excitation of Traveling Waves with an Annular Ladder Resonator for 7T Body Imaging with Reduced SAR

Introduction: The dimensions of the RF shield and the RF frequency for proton imaging at 7T allow the excitation of a propagating TE11 waveguide mode, which has given rise to the concept of traveling wave imaging [1]. RF excitation is typically achieved by using a patch antenna or crossed dipole antenna placed at one end of the bore [1, 2]. A nearly uniform B1 field is produced along the entire...

متن کامل

Traveling Wave Imaging of the Human Head at 7 Tesla: Assessment of SNR, Homogeneity and B1+ Efficiency

Introduction: The traveling wave concept for 7T MR imaging was first demonstrated by Brunner et al [1]. In the most common RF transmit coil designs, a quadrature RF field is created within a cylindrical volume in the near-field regime. In contrast, the traveling wave approach creates a traveling wave mode down the entire bore of the scanner. This has the potential to provide more uniform excita...

متن کامل

Comparison on the traveling wave excitation and the conventional excitation

Introduction: Traveling wave imaging has been suggested as a promising method for large FOV imaging in high field MR because in the empty bore it has a nearly constant magnitude along the propagating direction. However, the traveling wave system has thus far not been quantitatively compared with the conventional volume coil designs at high field to evaluate its performance in terms of efficienc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009