Evaluation of the Performance of Computed Radiography Systems with Different Sources and Different Configurations
نویسندگان
چکیده
Computed radiography (CR) is a digital radiographic technique, which uses very similar equipment to conventional radiography except that in place of a film to create the latent image, an imaging plate (IP) made of a photostimulable phosphor is used [1]. CR systems are commonly used in medical applications since they have proven reliability over more than two decades. Conversely, the NDT community has discussed the efficacy of film replacement by CR for more than 15 years. Though some standards were introduced in 2005 [ASTM E 2033, CEN EN 14784-2] and in 2013 [ISO 17636-2], CR is currently not included within the French RCCM although the technique is commonly used in US for nuclear applications according to ASME (Section V, article 2). Since 2006, AREVA has had a research and development project on this issue. This project aims to evaluate the performance differences between these two techniques within the framework of the NF standard EN 14784 for the CR and the RCCM for the film. The objective was to build a technical justification report to eventually support introduction of CR into the RCCM. In 2009 the subject gave rise to collaboration between AREVA NP – NETEC and EDFCEIDRE, for a joint project to establish performance limits of CR towards EN 14784 specifications and RCCM image quality indicator (IQI) requirements [2]. In this paper, we present performance comparison results of four different CR systems. The measurements were conducted in 2012 and they demonstrate the current states of achievable image quality in CR. Benchmark comparisons included two gamma sources (Selenium 75 and Iridium 192), and three different material thicknesses. Image quality was assessed in terms of EN 462 and ASTM (E 747, E 1742) IQI. The results have been scored considering ISO 17636-2, RCCM 2007, and ASME V-2010. This also permitted comparison among the different standards. Additionally, detectability measurements have been performed with the Selenium 75 gamma source and one system. Trials considered a real mock-up and different geometry configurations.
منابع مشابه
Review of transmission scanning configurations in cardiac SPECT
The diagnostic accuracy of single photon emission computed tomography (SPECT) is profoundly influenced by attenuation phenomenon. Soft tissue attenuation degrades cardiac SPECT image quality, thereby decreasing the possibility of the detection of the lesions. A variety of correction techniques based on different assumptions have been used to reduce the impact of attenuation. Several types of sy...
متن کاملThe Practice of Chest Radiography Using Different Digital Imaging Systems: Dose and Image Quality
Introduction: The study was undertaken to evaluate the practice of chest radiography using different digital imaging systems and its influence on dose and image quality. Materials and Methods: The study was carried out in two hospitals from March 2016 to June 2016. Sixty ambulatory patients aged 21 to 60 years who were able to cooperate without difficulty and weighed between 60 to 80 kg were ...
متن کاملComparison of cone beam computed tomography and digital radiography in detection of pulpal exposure in external cervical root resorption
Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the ...
متن کاملReliability assessment of power distribution systems using disjoint path-set algorithm
Finding the reliability expression of different substation configurations can help design a distribution system with the best overall reliability. This paper presents a computerized a nd implemented algorithm, based on Disjoint Sum of Product (DSOP) algorithm. The algorithm was synthesized and applied for the first time to the determination of reliability expression of a substation to determine...
متن کاملPerformance assessment of a SOFC cogeneration system for residential buildings located in eastern Iran
It is expected that residential units may replace traditional heat and power production systems with cogeneration ones. Among the different cogeneration systems, fuel cell based systems are a suitable choice due to their high efficiency, high power density, low emission and low noise. In this paper, a cogeneration system based on solid oxide fuel cells is examined. The system, including the f...
متن کامل