Development of a displacement-based design approach for modern mixed RC-URM wall structures
نویسندگان
چکیده
The recent re-assessment of the seismic hazard in Europe led for many regions of low to moderate seismicity to an increase in the seismic demand. As a consequence, several modern unreinforced masonry (URM) buildings, constructed with reinforced concrete (RC) slabs that provide an efficient rigid diaphragm action, no longer satisfy the seismic design check and have been retrofitted by adding or replacing URM walls with RC walls. Of late, also several new construction projects have been conceived directly as buildings with both RC and URM walls. Despite the widespread use of such construction technique, very little is known about the seismic behaviour of mixed RC-URM wall structures and codes do not provide adequate support to designers. The aim of the paper is therefore to propose a displacement-based design methodology for the design of mixed RC-URM edifices and the retrofit of URM buildings by replacing or adding selected URM walls with RC ones. The article describes also two tools developed for estimating important quantities relevant for the displacement-based design of structures with both RC and URM walls. The tools are (i) a mechanical model based on the shear-flexure interaction between URM and RC walls and (ii) an elastic model for estimating the contribution of the RC slabs to the overturning moment capacity of the system. In the last part of the article the proposed design method is verified through nonlinear dynamic analyses of several case studies. These results show that the proposed design approach has the ability of controlling the displacement profile of the designed structures, avoiding concentration of deformations in one single storey, a typical feature of URM wall structures.
منابع مشابه
Towards Displacement-Based Seismic Design of Modern Unreinforced Masonry Structures
Unreinforced masonry (URM) structures are known to be rather vulnerable to seismic loading. Modern URM buildings with reinforced concrete (RC) slabs might, however, have an acceptable seismic performance for regions of low to moderate seismicity. In particular in countries of moderate seismicity it is often difficult to demonstrate the seismic safety of modern URM buildings by means of force-ba...
متن کاملDirect Displacement Based Design of Reinforced Concrete Elevated Water Tanks Frame Staging
Elevated water tanks supported by the reinforced concrete (RC) Staging are classified as inverted pendulum structures. These are considered as structures of high post-earthquake importance and should remain functional after the seismic events. National codes of various countries recommend Force-Based Design (FBD) procedure for water tank staging, which does not ensure nonlinear performance leve...
متن کاملSeismic Behaviour and Design of Mixed RC-URM Wall Structures
............................................................................................................................ v Riassunto ......................................................................................................................... vii Résumé ............................................................................................................................. i...
متن کاملTwo Important Issues Relevant to Torsional Response of Asymmetric 8-Story RC BuildingDesigned with Direct Displacement based Design Approach
Direct displacement based design (DDBD) is a conceptual framework that directly design a structure to achieve an expected performance level under specified seismic intensity. In this study, two important issues relevant to torsional response of mass eccentric 8-story RC building designed with DDBD approach are investigated. These issues are including the effects of unbalanced mass distribution ...
متن کاملInfluence of coupling on the displacement capacities of URM piers – comparison of experimental results with existing recommendations
In existing European recommendations the drift capacity of unreinforced masonry (URM) piers is estimated as a function of the failure mode, aspect ratio and/or axial load ratio. The empirical relationships are based on a set of results from quasi-static cyclic tests on single URM piers, which were tested simulating either double-fixed or cantilever boundary conditions. In modern URM structures,...
متن کامل