Detector system dose verification comparisons for arc therapy: couch vs. gantry mount
نویسندگان
چکیده
The aim of this study was to assess the performance of a gantry-mounted detector system and a couch set detector system using a systematic multileaf collimator positional error manually introduced for volumetric-modulated arc therapy. Four head and neck and esophagus VMAT plans were evaluated by measurement using an electronic portal imaging device and an ion chamber array. Each plan was copied and duplicated with a 1 mm systematic MLC positional error in the left leaf bank. Direct comparison of measurements for plans with and without the error permitted observational characteristics for quality assurance performance between detectors. A total of 48 different plans were evaluated for this testing. The mean percentage planar dose differences required to satisfy a 95% match between plans with and without the MLCPE were 5.2% ± 0.5% for the chamber array with gantry motion, 8.12% ± 1.04% for the chamber array with a static gantry at 0°, and 10.9%± 1.4% for the EPID with gantry motion. It was observed that the EPID was less accurate due to overresponse of the MLCPE in the left leaf bank. The EPID always images bank-A on the ipsilateral side of the detector, whereas for a chamber array or for a patient, that bank changes as it crosses the -90° or +90° position. A couch set detector system can reproduce the TPS calculated values most consistently. We recommend it as the most reliable patient specific QA system for MLC position error testing. This research is highlighted by the finding of up to 12.7% dose variation for H/N and esophagus cases for VMAT delivery, where the mere source of error was the stated clinically acceptability of 1 mm MLC position deviation of TG-142.
منابع مشابه
The use of a silicon strip detector dose magnifying glass in stereotactic radiotherapy QA and dosimetry.
PURPOSE Stereotactic radiosurgery/therapy (SRS/SRT) is the use of radiation ablation in place of conventional surgical excision to remove or create fibrous tissue in small target volumes. The target of the SRT/SRS treatment is often located in close proximity to critical organs, hence the requirement of high geometric precision including a tight margin on the planning target volume and a sharp ...
متن کاملSU-E-T-549: On Importance of Accurate Treatment Couch Modeling in SmartArc VMAT Plans.
PURPOSE We investigate the impact of a treatment couch and its modeling in a treatment planning system on accurate dose delivery in Volumetric Modulated Arc Therapy (VMAT). METHODS A cone-beam CT of a Varian couch on a Varian Clinac 21EX unit, consisting of a carbon-fiber imaging couch top and supporting rails, was acquired, and a couch model was created in Philips Pinnacle 9.0 TPS based on t...
متن کاملQuantification and modelling of the dosimetric impact of the treatment couch in volumetric modulated arc therapy (VMAT)
Background: As the volumetric modulated arc therapy (VMAT) becoming a main role of treatment ways, the effect of couch top becomes more significant. It is imperative to re-evaluate the couches that previously may have been considered of no importance during early treatment techniques. The impact of couch top on radiation delivery was explored and the couch model was tested with the aim of reduc...
متن کاملSimultaneous couch and gantry dynamic arc rotation (CG‐Darc) in the treatment of breast cancer with accelerated partial breast irradiation (APBI): a feasibility study
The purpose of this study was to compare the dosimetry of CG-Darc with three-dimensional conformal radiation therapy (3D CRT) and volumetric-modulated arc therapy (RapidArc) in the treatment of breast cancer with APBI. CG-Darc plans were generated using two tangential couch arcs combined with a simultaneous noncoplanar gantry arc. The dynamic couch arc was modeled by consecutive IMRT fields at ...
متن کاملAngular dose dependency of MatriXX TM and its calibration
One of the applications of MatriXX (IBA Dosimetry) is experimental verification of dose for IMRT, VMAT, and tomotherapy. For cumulative plan verification, dose is delivered for all the treatment gantry angles to a stationary detector. Experimental calibration of MatriXX detector recommended by the manufacturer involves only AP calibration fields and does not address angular dependency of MatriX...