Electrical Circuit Flashover Model of Polluted Insulators under AC Voltage Based on the Arc Root Voltage Gradient Criterion
نویسندگان
چکیده
In order to study the flashover mechanism of polluted insulators under AC voltage, a new arc propagation criterion which is based on an arc root voltage gradient is proposed. This criterion can explain the variation of the arc root voltage gradient in the arc propagation process. Based on this criterion, a new distributed parameter electrical circuit flashover model of polluted insulators is presented. The arc channel is considered as an equivalent distributed parameter circuit model instead of using the arc voltage-gradient equation. The parameters of the arc model are obtained from the electromagnetic field distribution of the arc and the gas discharge theories. The arc root is considered as parallel paths including the polluted layer. The variation of the voltage on the arc root is related to the capability of arc propagation. This model takes the microscopic mechanism of arc root ionization into consideration, which can improve the accuracy of the flashover model. The results obtained from the presented model are in good agreement with other mathematical and experimental results.
منابع مشابه
Computation of AC flashover voltage of polluted HV insulators using a dynamic arc model
Flashover of polluted insulators is still a serious threat to the safe operation of a power transmission system. Despite the extensive investigations carried out on the pollution performance of the insulators, the flashover characteristics are not well understood. Recent theoretical and experimental research on polluted insulators is yet to yield a perfect generalized mathematical model which c...
متن کاملAnalysis of Leakage Current to Predict Insulator Flashover Using Artificial Neural Network
Problem statement: The phenomenon of flashover in polluted insulators has been continued by the study of the characteristics of contaminating layers deposited on the surface of insulators in high voltage laboratories. In the literature, Experimental investigations have been carried out on a real insulator or a flat plate model of insulators under high voltage application. This study proposed th...
متن کاملFlashover Characteristics of Silicone Rubber Sheets under Various Environmental Conditions
Silicone rubber insulators are replacing the conventional ceramic and porcelain insulators rapidly in power transmission and distribution industry. Very limited field knowledge is available about the performance of silicone rubber insulators in polluted and contaminated environments and therefore need further investigation. A comprehensive analysis of silicone rubber sheets (intended for coatin...
متن کاملDesignation of an Indicator for flashover prediction of porcelain and glass insulators based on experimental tests.
Flashover of polluted insulators in contaminated areas is one of the most important factors influencing the operation of transmission and distribution lines and finally line outages. Therefore, it is essential to prevent and detect flashover in the insulators. Hence, utilizing the insulator status monitoring systems and predicting their functions have absorbed a lot of attention over the recent...
متن کاملFlashover Voltage Estimation by Artificial Neural Network of Polluted Post Insulators Transmission Lines at High Altitude Area
In this work an attempt has been made to estimate the pollution flashover voltage under various meteorological factors using radial basis function (RBF) neural networks. Orthogonal least squares (OLS) learning method is used in order to improve the lines performance against the pollution flashover of the post insulators. The technique of RBF neural network is employed to model the relationship ...
متن کامل