Correlation of Methods of Glomerular Filtration Rate Estimation - 24 h Urinary Creatinine Clearance, Predicted Creatinine Clearance Method (Cockcroft-Gault), and Camera Based TC-99m- diethylenetriaminepentaacetic Acid Renography in Patients of Diabetic Nephropathy

نویسندگان

  • A V S Anil Kumar
  • Sangeetha Sampath
  • P G Kumar
چکیده

Introduction: Glomerular filtration rate (GFR) is the most important measure for early detection of deterioration of renal function. Patients with diabetic nephropathy need to be intensely monitored with GFR value. Many methods are used to estimate the GFR, all having their own advantages and constraints. The correlation of these methods with each other in patients with diabetic nephropathy needs to be studied. Purpose: To correlate three widely used methods of GFR estimation, namely 24 h urinary creatinine clearance (CrCl), predicted CrCl method (Cockcroft-Gault [CG]), and camera based Tc-99m-diethylenetriaminepentaacetic acid (DTPA) renography (by Gates’ protocol), in cases of diabetic nephropathy and to study the effect of duration of disease on renal function. Materials and Methods: A total of 52 cases of diabetic nephropathy were studied, and GFR was estimated by all the above three methods simultaneously. Correlation between variables was performed using commercially available statistical software (Minitab 15). Bland-Altman recommendations were used to compare the GFR calculated with CG formula and 24 h CrCl with the TC-99m-DTPA renogram method. Pearson’s correlation was used to assess the relationship between variables. Results: The mean GFR obtained with 99mTc-DTPA renogram, 24 h CrCl, and CG method were 63.24 ml/min ± 22.39 ml/min, 43.06 ± 13.83 ml/min, and 54.87 ± 18.25 ml/min, respectively. There was a significant correlation between GFR by 99mTc-DTPA versus endogenous CrCl (P < 0.001, r = 0.830) and 99mTc-DTPA versus CG formula (P < 0.001, r = 0.919). Conclusion: There is a wide variation in the absolute values of GFR obtained by the three methods although all the three methods correlate well with each other. If the same method is used for follow-up, it is highly reliable in detecting the deterioration of renal function from the baseline value. However, these methods cannot be used interchangeably.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of methods for determination of glomerular filtration rate: Tc-99m-DTPA renography, predicted creatinine clearance method and plasma sample method.

BACKGROUND The gamma camera uptake method with Tc-99m-DTPA is simple and less time consuming for the determination of the glomerular filtration rate (GFR). However, its diagnostic accuracy is debated. Gates' method and predicted creatinine clearance method were compared with plasma clearance method with Tc-99m-DTPA for the measurement of GFR. MATERIALS AND METHODS Tc-99m-DTPA renography was p...

متن کامل

Comparisons between validated estimated glomerular filtration rate equations and isotopic glomerular filtration rate in HIV patients.

OBJECTIVE Understanding how best to measure renal function in HIV-infected patients is critical because estimated glomerular filtration rate (eGFR) in HIV-infected patients can be affected by ethnicity and body composition. We validated the available eGFR equations and compared them to the plasma Tc-diethylenetriaminepentaacetic acid (Tc-DTPA) clearance in HIV-infected patients. DESIGN Test o...

متن کامل

A comparison of the predictive performance of different methods of kidney function estimation in a well-characterized HIV-infected population.

BACKGROUND Glomerular filtration rate (GFR) estimation equations have never been validated in the HIV population. This pilot study aimed to compare all currently available methods of kidney function assessment with nuclear GFR in HIV-infected adults. METHODS Patients underwent GFR measurement with (99m)Tc-diethylenetriaminepentaacetic acid (Tc-99m Pentetate), and measured values were compared...

متن کامل

The glomerular filtration rate: comparison of various predictive equations based on serum creatinine with conventional creatinine clearance test in Pakistani population.

INTRODUCTION To compare the conventional creatinine clearance measured on 24-h urine collection with the estimated Glomerular Filtration Rate by Cockcroft & Gault (CG) and Modification of Diet in Renal Disease (MDRD) prediction equations in adults aged 20 years and above in Pakistani population. METHODS All the patients, including inpatient admitted in hospital and outpatients, more than 20 y...

متن کامل

Kidney function: glomerular filtration rate measurement with MR renography in patients with cirrhosis.

PURPOSE To assess the accuracy of glomerular filtration rate (GFR) measurements obtained with low-contrast agent dose dynamic contrast material-enhanced magnetic resonance (MR) renography in patients with liver cirrhosis who underwent routine liver MR imaging, with urinary clearance of technetium 99m ((99m)Tc) pentetic acid (DTPA) as the reference standard. MATERIALS AND METHODS This HIPAA-co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016