Calibrated Digital Imaging Systems

نویسنده

  • Masato Kobori
چکیده

The concept of simulating chosen information channels of a linear incoherent imaging system by projecting reference signals is proposed and the system's ability to restore severely distorted but stationary images is experimentally demonstrated. A particular instrument's object field is divided into N discrete 'points' whose individual simulated outputs is measured at N particular sampling points; the NxN output matrix F is the transfer matrix of the system, and being empirically derived, it precisely accounts for all diffractions, aberrations, distortions, peculiarities of the chosen object points and sensor size and distribution. As such F can become the basis for eliminating algorithmhardware mismatch in various restoration schemes. Calibration allows treating the instrument as an unknown 'black box', and imaging through a severely and arbitrarily distorting hardware is demonstrated. Other uses of F are to add or subtract the outputs of separate instruments viewing the same object on a pixel-by-pixel basis, and as a graphically or digitally presented measure of the instrument's local transfer function, and hence of image quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of Dose and Image Quality in Full-fiand Computed Radiography Systems for Common Digital Radiographic Examinations

IntroductionA fine balance of image quality and radiation dose can be achieved by optimization to minimize stochastic and deterministic effects. This study aimed in ensuring that images of acceptable quality for common radiographic examinations in digital imaging were produced without causing harmful effects. Materials and MethodsThe study was conducted in three phases. The pre-optimization inv...

متن کامل

A Comparison of Patients Absorption Doses with Bone Deformity Due to the EOS Imaging and Digital Radiology

  Background: This study has aimed to measure the patient dose in entire spine radiography by EOS system in comparison with the digital radiography. Methods: EOS stereo-radiography was used for frontal and lateral view spine imaging in 41 patients in a prospective analytical study. A calibrated dose area product (DAP) meter was used for calibration of the DAP in EOS system. The accuracy and pr...

متن کامل

The Practice of Chest Radiography Using Different Digital Imaging Systems: Dose and Image Quality

Introduction: The study was undertaken to evaluate the practice of chest radiography using different digital imaging systems and its influence on dose and image quality.  Materials and Methods: The study was carried out in two hospitals from March 2016 to June 2016. Sixty ambulatory patients aged 21 to 60 years who were able to cooperate without difficulty and weighed between 60 to 80 kg were ...

متن کامل

Enhanced Absolute and Relative Radiometric Calibration for Digital Aerial Cameras

A new laboratory radiometric calibration process has been developed at Intergraph Z/I Imaging and is being implemented for both the DMC and RMK-D camera systems. This new capability enables the development of absolutely radiometrically calibrated products for scientific and remote sensing applications and improves general image color quality and color balance. Although many advanced CCD-based m...

متن کامل

High Dynamic Range Imaging of Natural Scenes

The ability to capture and render high dynamic range scenes limits the quality of current consumer and professional digital cameras. The absence of a well-calibrated high dynamic range color image database of natural scenes is an impediment to developing such rendering algorithms for digital photography. This paper describes our efforts to create such a database. First, we discuss how the image...

متن کامل

Comparison of cone beam computed tomography and digital radiography in detection of pulpal exposure in external cervical root resorption

Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011