Force-dependent static dead space of face masks used with holding chambers.

نویسندگان

  • Samir A Shah
  • Ariel B Berlinski
  • Bruce K Rubin
چکیده

BACKGROUND Pressurized metered-dose inhalers with valved holding chambers and masks are commonly used for aerosol delivery in children. Drug delivery can decrease when the dead-space volume (DSV) of the valved holding chamber is increased, but there are no published data evaluating force-dependent DSV among different masks. METHODS Seven masks were studied. Masks were sealed at the valved holding chamber end and filled with water to measure mask volume. To measure mask DSV we used a mannequin of 2-year-old-size face and we applied the mask with forces of 1.5, 3.5, and 7 pounds. Mask seal was determined by direct observation. Intra-brand analysis was done via analysis of variance. RESULTS At 3.5 pounds of force, the DSV ranged from 29 mL to 100 mL, with 3 masks having DSV of < 50 mL. The remaining masks all had DSV > 60 mL. At 3.5 pounds of force, DSV percent of mask volume ranged from 33.7% (Aerochamber, p < 0.01 compared with other masks) to 100% (Pocket Chamber). DSV decreased with increasing force with most of the masks, and the slope of this line was inversely proportional to mask flexibility. Mask fit was 100% at 1.5 pounds of force only with the Aerochamber and Optichamber. Mask fit was poorest with the Vortex, Pocket Chamber, and BreatheRite masks. CONCLUSION Rigid masks with large DSV might not be not suitable for use in children, especially if discomfort from the stiff mask makes its use less acceptable to the child.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dead space variability of face masks for valved holding chambers.

BACKGROUND Valved holding chambers with masks are commonly used to deliver inhaled medications to young children with asthma. Optimal mask properties such as their dead space volume have received little attention. The smaller the mask the more likely it is that a greater proportion of the dose in the VHC will be inhaled with each breath, thus speeding VHC emptying and improving overall aerosol ...

متن کامل

Review of optimal characteristics of face-masks for valved-holding chambers (VHCs).

Inhaled drugs are frequently given to infants and young children with a pressurized metered-dose inhaler (pMDI) attached to a valved-holding chamber (VHC) with face mask. In young children and infants who cannot breathe through a mouthpiece, the face mask serves as the interface between the patient and the VHC. Although the mask interface is one of the most important factors determining the dos...

متن کامل

Dynamic dead space in face masks used with noninvasive ventilators: a lung model study.

The aim of this study was to determine what the influence of different designs of face masks and different noninvasive ventilator modes would be upon total dynamic dead space. Using a spontaneous breathing model, total dynamic dead space was measured when using 19 commercially available face masks and a range of ventilators in various ventilation modes. Total dynamic dead space during spontaneo...

متن کامل

Design of aerosol face masks for children using computerized 3D face analysis.

BACKGROUND Aerosol masks were originally developed for adults and downsized for children. Overall fit to minimize dead space and a tight seal are problematic, because children's faces undergo rapid and marked topographic and internal anthropometric changes in their first few months/years of life. Facial three-dimensional (3D) anthropometric data were used to design an optimized pediatric mask. ...

متن کامل

Infant aerosol holding chamber face masks: not all are born equal!

Face masks are used for many respiratory care applications, such as anesthesia, resuscitation, and aerosol therapy. In pediatric practice, particularly with infants and toddlers, aerosol therapy is usually administered by means of a small-volume nebulizer and face mask. Because of their convenience, speed of administration, versatility, dose accuracy, reproducibility, near-optimal mass median a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 51 2  شماره 

صفحات  -

تاریخ انتشار 2006