Sensitivity and specificity of two dried blood spot methods for HIV-1 viral load monitoring among patients in Hanoi, Vietnam
نویسندگان
چکیده
The use of dried blood spot (DBS) specimens for HIV viral load (VL) monitoring is recommended to support the roll-out of routine VL monitoring in low and middle income countries (LMICs). To better understand the use of DBS for VL monitoring, we evaluated two DBS testing methods, Roche TaqMan® Free Virus Evolution protocol (DBS-FVE) and Roche TaqMan® SPEX protocol (DBS-SPEX)) in patients receiving ART at an HIV clinic in Hanoi, Vietnam. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for each DBS testing method at the thresholds of 1000 and 5000 copies/ml compared to plasma VL. At a threshold of 1000 copies/ml, sensitivity, specificity, PPV and NPV of the DBS-SPEX method were 98.8% (95% CI: 93.3%-100%), 74.3% (95% CI: 70.8%-77.5%), 31.5% (95% CI: 25.8%-37.6%), and 99.8% (95% CI: 98.9%-100%), respectively. Increasing the VL threshold value to 5000 copies/ml improved specificity (97.9% CI: 96.6%-98.9%) and PPV (83.9% CI: 74.5%-90.9%). Using the DBS-FVE method, at the threshold of 1000 copies/ml and with a correction factor of +0.3 log copies/ml, sensitivity was 95.1% (87.8%-98.6%) and specificity was 98.8% (97.7%-99.5%). Sensitivity decreased at the threshold of 5000 copies/ml (65.8%, 95% CI: 54.3%-76.1%). With a correction factor of +0.7 log copies/ml, the sensitivity was 96.3% (89.6%-99.2%) and specificity was 98.2% (96.9%-99.1%) at the threshold of 1000 copies/ml. We found that the Roche DBS-FVE method, with a +0.7 log copies/ml correction factor, performed well with sensitivity and specificity greater than 96% at a VL threshold of 1000 copies/m. These findings add to the growing body of evidence supporting the use of DBS VL testing for ART monitoring. Future research should evaluate the association between VL results by DBS and clinical outcome measures such as HIV drug resistance, morbidity, and mortality.
منابع مشابه
Evaluation of Two Techniques for Viral Load Monitoring Using Dried Blood Spot in Routine Practice in Vietnam (French National Agency for AIDS and Hepatitis Research 12338)
Background. Although it is the best method to detect early therapeutic failure, viral load (VL) monitoring is still not widely available in many resource-limited settings because of difficulties in specimen transfer, personnel shortage, and insufficient laboratory infrastructures. Dried blood spot (DBS) use, which was introduced in the latest World Health Organization recommendations, can over...
متن کاملFirst field evaluation of the optimized CE marked Abbott protocol for HIV RNA testing on dried blood spot in a routine clinical setting in Vietnam
BACKGROUND Viral load (VL) monitoring of HIV-infected patients in decentralized areas is limited due to logistic constraints. Dried Blood Spots (DBS) offer the opportunity to collect samples in remote area which can be easily transferred and tested at a central laboratory. The MOVIDA (Monitoring Of Viral load In Decentralized Area) project evaluated the performance of VL measurements on DBS usi...
متن کاملPerformance and Logistical Challenges of Alternative HIV-1 Virological Monitoring Options in a Clinical Setting of Harare, Zimbabwe
We evaluated a low-cost virological failure assay (VFA) on plasma and dried blood spot (DBS) specimens from HIV-1 infected patients attending an HIV clinic in Harare. The results were compared to the performance of the ultrasensitive heat-denatured p24 assay (p24). The COBAS AmpliPrep/COBAS TaqMan HIV-1 test, version 2.0, served as the gold standard. Using a cutoff of 5,000 copies/mL, the plasm...
متن کاملDried blood spot HIV-1 RNA quantification: A useful tool for viral load monitoring among HIV-infected individuals in India
BACKGROUND & OBJECTIVES Monitoring of HIV-infected individuals on antiretroviral treatment (ART) ideally requires periodic viral load measurements to ascertain adequate response to treatment. While plasma viral load monitoring is widely available in high-income settings, it is rarely used in resource-limited regions because of high cost and need for sophisticated sample transport. Dried blood s...
متن کاملMeasurement of viral load by the automated Abbott real-time HIV-1 assay using dried blood spots collected and processed in Malawi and Mozambique.
BACKGROUND The use of dried blood spots (DBS) for HIV-1 viral load quantification can greatly improve access to viral monitoring for HIV-infected patients receiving treatment in resource-limited settings. OBJECTIVES To evaluate and validate HIV viral load measurement from DBS in sub-Saharan Africa, with a reliable, all-automated, standard commercial assay such as the Abbott m2000. METHODS A...
متن کامل