The impact of lesion vascularisation on tumours detection by electrical impedance scanning at 200 Hz

نویسندگان

  • A Malich
  • B Scholz
  • A Kott
  • M Facius
  • DR Fischer
  • MG Freesmeyer
چکیده

OBJECTIVE Cancer cells exhibit altered local dielectric properties compared to normal cells. These properties are measurable as a difference in electrical conductance using electrical impedance scanning (EIS). EIS is at present not sufficiently accurate for clinical routine despite its technological advantages. To modify the technology and increase its accuracy, the factors that influence precision need to be analysed and identified. While size, depth, localisation and invasiveness affect sensitivity, vascularisation might show an increased conductance and thus might affect specificity. SUBJECTS AND METHODS All patients were investigated with EIS (TransScan TS 2000, Migdal Ha Emek, Israel) Planned DCE-MRI prior to histological clarification were included (295 lesions). Dynamic enhancements were assigned scores after analysis of subtracted images after application of Gd-DTPA. D1: strong enhancement of >100% from initial signal obtained on native T1weighted sequence; D2: moderate enhancement 50-100%; D3: enhancement similar to glandular tissue, <50%; D4: subtle or no enhancement, less then surrounding glandular tissue. RESULTS 89/113 malignant and 107/182 benign findings were visible by a focal increased conductance and/or capacitance using EIS (Sensitivity 79%, Specificity 59%). DCE-MRI was aborted due to claustrophobia in 17/295 cases. MR was used and out of 278 completed MR examinations, 101/104 malignant and 141/174 benign lesions were correctly diagnosed as benign or malignant leading to a sensitivity of 97% and a specificity of 81%. D1 benign lesions were positive in EIS in 33/55 cases suggesting a specificity of 44.4%. This value increases significantly with decreased vascularity to 68.9% (D2-4; 82/119). Out of 60 fibroadenomatous lesions, 10/23 fibroadenomas in class 1 had no focal increased conductance or capacitance and were thus considered as non-suspicious in EIS. The same result was applicable for the 29/37 benign lesions with a D2-4 contrast uptake (43.5% vs. 78.4%, p<.01). CONCLUSION Vascularisation influences the measurable conductance at low frequency and therefore partially causes the insufficiently low specificity of EIS. Impedance measurements at frequencies in a range of 0.1 KHz to 1 MHz are required . According to theoretical and in vitro studies this might increase the accuracy of EIS technology. © 2007 Biomedical Imaging and Intervention Journal. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the use of gold nanoparticle as contrast agent in electrical impedance imaging

Introduction: Electrical Impedance Tomography (EIT) is a real time and minimal invasive imaging modality for detection of lesions in tissues even when their structures show no changes. Early detection of lesion with EIT depends on difference between electrical impedance of targeted tissue and its surroundings. Therefore, finding a contrast agent for EIT that increase this diffe...

متن کامل

Stress Corrosion Cracking Detection of Sensitized Stainless Steel 304 in Chloride Media by Using Electrochemical Impedance Spectroscopy (EIS)

Electrochemical impedance spectroscopy (EIS) was used to detect stress corrosion cracking (SCC) in stainless steel 304 alloy exposed to an aqueous environment at 120 °C. Stainless steel 304 alloy as u-bend was tested in the solution that contains 40 weight percent of magnesium chloride. U-bended samples were prepared according to ASTM G30. EIS measurements were always performed simultaneously o...

متن کامل

The Effect of Gold Nanoparticle on Electrical Impedance of Tissue on Low Frequency Ranges

Introduction: Electrical impedance of tissues on low frequencies includes useful information about functional and structural changes in tissues. This property is used in Electrical Impedance Tomography (EIT) imaging modality for the detection of lesions in tissues.Objective: The goal of this article is to study changes in electrical impedance of tissues in the presence of gold nanoparticles.Mat...

متن کامل

A Novel Resistive Capacitive Feedback Trans-impedance Amplifier Optimization Using IPSO Algorithm

A novel low noise trans-impedance amplifier is proposed using low cost 0.18 µm CMOS technology. A resistive-capacitive feedback is used to extend the bandwidth of the amplifier. As the structure is inductor less, it is suitable for low cost integrated optical interconnects. In this paper Improved Particle Swarm Optimization have applied to determine optimal trans-resistance and noise of propose...

متن کامل

Modified Impedance-Based OOS Protection Based on On-Line Thévenin Equivalent Estimation

In this paper, a novel approach based on the Thévenin tracing is presented to modified conventional impedance-based out-of-step (OOS) protection. In conventional approach, the OOS detection is done by measuring positive sequence impedance. However, the measured impedance may be change due to different factors such as capacitor bank switching and reactive power compensators that it can cause the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2007