PURPOSE To study the long-term results of photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) in low to moderate myopic corrections using the Pulzar Z1 system (CustomVis), a 213 nm wavelength solid-state laser. SETTING University refractive surgery center. METHODS This prospective noncomparative case series comprised 20 patients (40 eyes) who had refractive surgery using the Pulzar Z1 laser system. Manifest refraction, uncorrected visual acuity, best spectacle-corrected visual acuity (BSCVA), safety, predictability, stability, and confocal microscopy images were evaluated. RESULTS Ten patients (20 eyes) had PRK and 10 patients (20 eyes) had LASIK. The mean follow-up was 13.9 months +/- 1.1 (SD) (range 12 to 17 months) and 14.6 +/- 1.2 months (range 12 to 18 months) in the PRK group and LASIK group, respectively. No eye lost a line of Snellen BSCVA during the follow-up period; 2 eyes (10%) gained 2 Snellen lines. There was a statistically significant decrease in spherical equivalent manifest refraction postoperatively in both groups (P<.05). Refractive stability was obtained during the first postoperative month and remained stable during the follow-up period, with no significant changes between any interval in both groups (P>.05). At the last follow-up, 95% of all eyes were within +/-1.00 diopter of emmetropia. No late postoperative complications were observed. CONCLUSION Refractive surgery using the Pulzar Z1 213 nm wavelength solid-state laser was a safe, effective procedure in the treatment of low to moderate myopia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endothelial cell density after photorefractive keratectomy for moderate myopia using a 213 nm solid-state laser system.

PURPOSE To evaluate whether photorefractive keratectomy (PRK) for moderate myopia using a solid-state laser with a wavelength of 213 nm alters the corneal endothelial cell density. SETTING University refractive surgery center. METHODS The corneal endothelium was analyzed preoperatively and 1, 6, and 12 months postoperatively using corneal confocal microscopy (modified HRT II with a Rostock ...

متن کامل

Photorefractive Keratectomy with Adjunctive Mitomycin C for Residual Error after Laser-Assisted In Situ Keratomileusis Using the Pulzar 213 nm Solid-State Laser: Early Results

Purpose. To evaluate the accuracy, efficacy, stability, and safety of photorefractive keratectomy (PRK) enhancement using the Pulzar 213 nm solid-state laser (SSL) with adjunctive Mitomycin C in eyes previously treated with laser assisted in situ keratomileusis (LASIK) with residual error of refraction. Methods. This is a prospective noncomparative case series of 16 eyes of 12 patients who unde...

متن کامل

نتایج عمل Photorefractive keratectomy برای درمان نزدیک بینی زیاد در کلینیک نور تهران

Many studies have shown the effectiveness of photorefractive keratectomy (PRK) in correction of vision in low and moderate Myopia. To evaluate the results of 193-nm exeimer laser photorefractive keratectomy for highly Myopic eyes, we reviewed refractive outcome of 43 eyes of 30 patients. Most eyes were treated with 1-step operation, using a 6 mm optical zone. 43 eyes were treated for Myopia, wh...

متن کامل

Photorefractive keratectomy using solid state laser 213 nm and excimer laser 193 nm: a randomized, contralateral, comparative, experimental study.

PURPOSE To compare histopathologic changes after photorefractive keratectomy (PRK) for myopia using either a solid state laser (SSL) at 213 nm or an excimer laser (EL) at 193 nm in an experimental model. METHODS Forty pigmented rabbits (80 eyes) underwent myopic PRK for the correction of 6 D. Photoablation was randomly assigned, with a solid state laser used in one eye and an EL in the fellow...

متن کامل

Comparison of corneal wavefront aberrations after photorefractive keratectomy and laser in situ keratomileusis.

PURPOSE To compare changes in the corneal wavefront aberrations after photorefractive keratectomy and laser in situ keratomileusis. METHODS In a prospective randomized study, 22 patients with bilateral myopia received photorefractive keratectomy on one eye and laser in situ keratomileusis on the other eye. The procedure assigned to each eye and the sequence of surgery for each patient were ra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 33 6  شماره 

صفحات  -

تاریخ انتشار 2007