Discussion: session 1. Detection of health effects of exposure to low doses of agents—scientific constraints*

نویسنده

  • J. A. DICKSON
چکیده

-The postulate that low intracellular pH acts as a preconditioner for the destructive effects of hyperthermia (42°C) was examined, using a heat-sensitive line of malignant cells derived from rat mammary gland (SDB). Intracellular pH (pHi) was measured indirectly, from the distribution of the weak, non-metabolizable organic acid 5,5-dimethyl-2,4-oxazolidinedione (DMO) between intraand extracellular water. Respiration, aerobic and anaerobic glycolysis of the cells were studied at normal pHi (pH 7.0-7.4) or at low pHi (pH 6.2-6.6) and at 38°C or 42°C over 6 h in Warburg manometers; the ability of the cells to replicate in culture was examined after 3 h or 6 h incubation in the flasks. The relationship between pHi and extracellular pH (pHe) depended upon the buffer system used and the exact pH in question; no assumption regarding pHi based only on pHe measurement could be made. At 38°C and low pHi, the Pasteur effect became negative due to a relatively greater inhibition of anaerobic than aerobic glycolysis. Respiration was unaffected and cell replicative ability unimpaired. At 42°C and normal pHi, respiration was totally inhibited after 4 h and the Pasteur effect was decreased, in this case due to a compensatory increase in aerobic glycolysis without alteration in anaerobic CO2 production. Low pHi in the presence of hyperthermia enabled cell respiration to continue at a reduced level with no further change in glycolysis. There was delayed cell replication after 3 h at 42°C and inability to multiply following 6 h hyperthermia: low pHi did not influence these results. It is concluded that with these cancer cells, pHi values maintained in the region of 1.0 pH unit below normal for 6 h had no deleterious effect on the cells. No sensitizing effect of the low pHi for the destructive effect of hyperthermia on the cells was observed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation hormesis and adoptive response induced by low doses of limiting radiation

  Ionizing radiation has long been known to produce detrimental biological effects. Although these harmful effects are the results of high doses of exposure, some other maladies such as mutation and cancer seems  to be induced at low doses of exposure. In recent decades, however, some pioneer scientists have indicated that ionizing radiation like many other essential agents has toxic effects  ...

متن کامل

Health risk assessment of occupational exposure to harmful chemical agents in a pesticide manufacturing plant

Background: In most industries, employees are in contact with various chemical agents. The objective of this study was to assess the health risks posed by occupational exposure to harmful chemical agents in a pesticide manufacturing plant in Zahedan, Iran, in 2013. Materials and Methods: This cross-sectional study was conducted in different units of a pesticide manufacturing plant. In order to...

متن کامل

Quantitation of genome damage and transcriptional profile of DNA damage response genes in human peripheral blood mononuclear cells exposed in vitro to low doses of neutron radiation

Background: Humans are exposed to ionizing radiation from different sources that include natural, occupational, medical, accidental exposures. Evaluation of the effect of low level of neutron exposure to human cells in vitro has important implications to human health. Attempts were made to measure genome damage, transcriptional profile of DNA damage response and repair genes in peripheral blood...

متن کامل

Assessment of Extremely Low Frequency (ELF) Electric and Magnetic Fields in Hamedan High Electrical Power Stations and their Effects on Workers

Introduction: Public and occupational exposure to extremely low frequency (ELF) electric and magnetic fields induced by electrical equipment is a significant issue in the environment and at the workplace due to their potential health effects on public health. The purpose of this study was assessment of the electric and magnetic fields intensities and determination of mental and psychological ef...

متن کامل

Investigation of combined effects of noise and low air temperature on human-environmental comfort and physiological responses- An experimental study

Background and Aim: Combined exposure to noise and temperature can affect the neurophysiological responses of the office staff. The present study was done to investigate the impacts of combined exposure to noise and low air temperature on physiological responses and environmental comfort. Methods: In this experimental study, the studied population included the students who were randomly selecte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental Health Perspectives

دوره 42  شماره 

صفحات  -

تاریخ انتشار 1981