Suprachoroidal hemorrhage during femtosecond laser assisted cataract surgery
نویسندگان
چکیده
Purpose To describe a case of suprachoroidal hemorrhage that occurred during femtosecond laser assisted cataract surgery (FLACS). Observations A 67-year-old woman with high myopia underwent FLACS. Following two unsuccessful attempts at docking due to interface air bubbles, the third attempt was successful. Laser treatment and cataract surgery proceeded uneventfully until intraocular lens (IOL) implantation. While positioning the IOL within the capsular bag, the anterior chamber began to shallow, intraocular pressure became high by palpation, and the optic of the IOL prolapsed partially out of the bag. A segmental suprachoroidal hemorrhage was identified in the superior peripheral retina by intraoperative indirect ophthalmoscopy. Following an hour of waiting in the recovery room, the anterior chamber deepened and the intraocular pressure was low enough to position the IOL centrally within the bag. Her subsequent postoperative course was uneventful. Conclusions and Importance To our knowledge, this is the first report of suprachoroidal hemorrhage during FLACS. We speculate that repeated sudden drops in intraocular pressure associated with multiple undockings triggered the suprachoroidal hemorrhage in this case.
منابع مشابه
Femtosecond laser-assisted cataract surgery in anterior lenticonus due to Alport syndrome
Purpose We describe a case of bilateral anterior lenticonus in a patient with Alport syndrome treated with femtosecond laser-assisted cataract surgery (FLACS). Observations FLACS was performed without complication, and a desirable postoperative visual acuity was achieved. Conclusions and importance Femtosecond laser-assisted cataract surgery is an effective approach for managing patients wi...
متن کاملPreliminary Results of Femtosecond Laser-assisted Cataract Surgery in a Private Clinic in Iran
PURPOSE To report the preliminary results of femtosecond laser-assisted cataract surgery in Iranian patients. METHODS This prospective case series included 21 eyes of 21 patients with cataract. Mean patient age was 66.7 ± 10 years. The patients underwent femtosecond-laser assisted cataract surgery (VICTUS Femtosecond Laser Platform: Bausch + Lomb) and intraocular lens (IOL) implementation in ...
متن کاملOptical patient interface in femtosecond laser-assisted cataract surgery: contact corneal applanation versus liquid immersion.
PURPOSE To compare 2 optical patient interface designs used for femtosecond laser-assisted cataract surgery. SETTING Optimedica Corp., Santa Clara, California, USA, and Centro Laser, Santo Domingo, Dominican Republic. DESIGN Experimental and clinical studies. METHODS Laser capsulotomy was performed during cataract surgery with a curved contact lens interface (CCL) or a liquid optical imme...
متن کاملSafety of femtosecond laser-assisted cataract surgery performed by surgeons in training.
Femtosecond laser-assisted cataract surgery has grown in popularity among ophthalmologists as a novel technique with the potential to reduce phacoemulsification energy requirements.1,2 However, early adoption of femtosecond laser-assisted cataract surgery by experienced cataract surgeons has been associated with a significant learning curve.3 Roberts et al. reported higher complication rates in...
متن کاملTissue plasminogen activator-assisted vitrectomy in the early treatment of acute massive suprachoroidal hemorrhage complicating cataract surgery.
Dear Editor, I am Dr. Zhao PQ, from the Department of Ophthalmology, Xin Hua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China. I write to present a case report of tissue plasminogen activator (tPA)-assisted vitrectomy in the early treatment of acute massive suprachoroidal hemorrhage (SCH) complicating cataract surgery. SCH is a vision-threatening complica...
متن کامل