Hygroscopic expansion of a compomer and a composite on artificial gap reduction.
نویسندگان
چکیده
OBJECTIVE This study compared the effect of water sorption on the extent of marginal gap reduction in a compomer (Dyract AP, Dentsply) and a composite (Spectrum, Dentsply) over a 12-week storage period. MATERIALS AND METHODS Artificial gaps were created in 40 borosilicate glass cylinders, each 5mm deep and with an internal diameter of 5.5mm. Half of the internal bonding surface of each cylinder was sandblasted, silanised and coated with a dentine adhesive (Prime&Bond NT, Dentsply). Twenty partially bonded cylinders were incrementally filled with Dyract AP (AP) and the rest with Spectrum (S). For each material, 10 specimens were stored in de-ionised water (W), and 10 (control) in non-aqueous silicone fluid (O) at 37 degrees C. The dimension of the same maximum gap created in each specimen was repeatedly measured at 0, 1, 2, 4, 6, 8, 10 and 12 weeks, using a light microscope under incident light at 570x magnification. Gap widths in each of the four groups (n=10) were statistically compared. Correlations between mean gap width reduction and storage time were also examined. RESULTS Friedman repeated measures ANOVA on ranks revealed significant differences (p<0.001) among the gap widths measured at different time intervals in groups AP-W and S-W. No significant differences (p>0.05) were found in groups AP-O and S-O. Tukey's multiple comparison test indicated that no significant differences (p>0.05) were detectable beyond the sixth week in AP-W and the fourth week in S-W. Linear regression analyses showed that mean gap widths decreased exponentially with time for AP-W (r=0.97) and S-W (r=0.90). From the slopes of the regression lines, the rate of marginal gap reduction in AP-W was 4.6 times faster than S-W. CONCLUSION Marginal gap reduction in both the materials are directly attributed to water sorption and that the reduction is larger and more rapid in Dyract AP.
منابع مشابه
به کارگیری مدل آمیخته خطی چندسطحی در مقایسه آزمایشگاهی انبساط آبی سه نوع کامپوزیت
Background: Tooth damage is one of the most common reasons that patients visit the dentists. Nowadays composites are increasingly used in dentistry because they have the colour of tooth and are more compatible with tooth tissue. Hygroscopic expansion is one of the most reasons that reduce the efficacy of the composite. Main goal of this article is to compare the hygroscopic expansion ...
متن کاملEffective Expansion: Balance between Shrinkage and Hygroscopic Expansion.
The purpose of this study was to investigate the relationship between hygroscopic expansion and polymerization shrinkage for compensation of polymerization shrinkage stresses in a restored tooth. One resin-modified glass-ionomer (RMGI) (Ketac Nano, 3M ESPE), 2 compomers (Dyract, Dentsply; Compoglass, Ivoclar), and a universal resin-based composite (Esthet•X HD, Dentsply) were tested. Volumetric...
متن کاملمقایسه مدلهای داده های طولی در انبساط آبی سه کامپوزیت متداول
Background: Longitudinal studies are widely used in medical and social sciences. According to repeated measurements in these studies, independence assumption is not observed and therefore suitable models should be selected. In this study, application of marginal and transition models for analyzing the longitudinal data related to hygroscopic expansion of composite is shown. Methods: ...
متن کاملA comparison on the effects of blood contamination on microleakage of composite and compomer ClV restorations using an All-in-one adhesive
A comparison on the effects of blood contamination on microleakage of composite and compomer ClV restorations using an All-in-one adhesive Dr. V.Mortazavi* - Dr. MH.Fathi**- Dr. P.Taghavi***- Dr. L.Ghorbanian****- Associate professor of Operative Dentistry Dept.- Faculty of Dentistry- Isfahan University of Medical Sciences. ** - Assistant professor of Metalogy engineering Dept.- Isfahan In...
متن کاملA comparative study of the effects of QTH and LED light curing units on the surface hardness of colored compomer and Hybrid composites
Introduction: One factor affecting the degree of polymerization is the type of light-curing device. The aim of this study was to compare the effects of LED and QTH light curing units on the surface hardness of composite and compomer. Materials & Methods: In this experimental study, 30 samples of composite and compomer were divided into 3 groups of 10 each. One-half of the subgroups in each g...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of dentistry
دوره 30 1 شماره
صفحات -
تاریخ انتشار 2002