Determination of Ni Impurities Using Cadmium-Selective Electrode
نویسنده
چکیده
Taking into account the use of Nickel brasses in industry a great number of methods for the determination of Ni have been reported. More, theoretical predictions of free Cd increasing with decreasing salinity have been confirmed using cadmium selective electrodes. The method under proposal, for the determination of nickel ions in brass alloys consists of the following steps: Cu masking with sodium thiosulfate; Ni precipitation as nickel-dimethylglyoximate at pH = 5.6 with subsequent selective extraction in chloroform; treatment of the organic phase with HNO3 1M; determination of Ni by titration of the excess of EDTA at pH = 5.6 with a solution of Cd, in the presence of the cadmium-selective electrode. The experimental values showed low dispersion and therefore a good precision. The mean value of nickel content from 13 parallel aliquots of the brass sample was 1.79% which agreed well with those obtained by the atomic absorption spectrometry, 1.77%.
منابع مشابه
Uultra-trace determination of cadmium (II) in aqueous environmental samples by a new ion selective electrode based on nefazodone and 1-butyl-3-methylimidazolium hexafluorophosphate ionic liquid
Background and Objective: Cadmium is a potential environmental contaminant that causes adverse effects on the environment and the health of living organisms. Therefore, designing a simple and economic technique for its determination is very important. In this respect, a potentiometric sensor based on nefazodone as the ionophore and [BMIM]PF6 as the ionic additive were developed for the determin...
متن کامل(1E,2E) -bis (2-aminophenyl) N'1,N'2-dihydroxyethane bis (imidothioate) as a neutral carrier in ion-selective electrode for Ni(II) and it computational studies
A PVC membrane Ni(II) ion selective electrode has been constructed using (1E,2E)-bis(2-aminophenyl)N'1,N'2-dihydroxyethanebis as membrane carrier. The electrode exhibited a goodpotentiometric response for Ni(II) over a wide concentration range 1.0×10-4 to 1.0×10-1M with aslope of 29.4±0.5 mV/decade a and a working pH range of 6.5-9.0. It had a fast response time of≤20s. The best performance was...
متن کاملSimultaneous Adsorptive Stripping Differential Pulse Voltammetric Measurements of Trace Lead, Cadmium and Nickel in the Presence of 2-aminobenzoic Acid
In this study, 2-aminobenzoic acid (ABA) has been used as complexing ligand for simultaneousdetermination of metal ions by adsorptive cathodic stripping voltammetry (AdCSV), for the firsttime. Thus, a selective and sensitive procedure was presented for simultaneous determination oflead, cadmium and nickel using ABA and differential pulse-adsorptive cathodic strippingvolt...
متن کاملA Sensitive Simultaneous Determination of Uric Acid, Norepinephrine and Indomethacin using a Cadmium Sulfide Nanoparticles/Multi-Walled Carbon Nanotubes Modified Gold Electrode
In this study a novel method was developed to fabricate cadmium sulfide nanoparticles/multiwalled carbon nanotubes composite modified gold electrode (CdSNPs/MWCNTS/AuE) to measure trace amounts of norepinephrine(NE), indomethacin (IND), and uric acid (UA) simultaneously. Electrochemical investigations were carried out using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chron...
متن کاملSelective Determination of Dopamine in the Presence of Ascorbic Acid and Uric Acid at Neutral pH Using a Silver Nanoparticles-modified Carbon Paste Electrode
Developing simple, sensitive and selective sensing systems for dopamine is important due to its biological significance. In this work, a silver nanoparticles-modified carbon paste electrode (AgNPs-CPE) has been constructed and used to detect of dopamine (DA) in the simultaneous presence of ascorbic acid (AA) and uric acid (UA) at neutral pH 7.0 by cyclic voltammetry. The modified electrode show...
متن کامل