Apparent Thixotropic Properties of Saline/Glycerol Drops with Biotinylated Antibodies on Streptavidin-Coated Glass Slides: Implications for Bacterial Capture on Antibody Microarrays

نویسندگان

  • David M. Albin
  • Andrew G. Gehring
  • Sue A. Reed
  • Shu-I Tu
چکیده

The thixotropic-like properties of saline/glycerol drops, containing biotinylated capture antibodies, on streptavidin-coated glass slides have been investigated, along with their implications for bacterial detection in a fluorescent microarray immunoassay. The thixotropic-like nature of 60:40 saline-glycerol semisolid droplets (with differing amounts of antibodies) was observed when bacteria were captured, and their presence detected using a fluorescently-labeled antibody. Semisolid, gel-like drops of biotinylated capture antibody became liquefied and moved, and then returned to semisolid state, during the normal immunoassay procedures for bacterial capture and detection. Streaking patterns were observed that indicated thixotropic-like characteristics, and this appeared to have allowed excess biotinylated capture antibody to participate in bacterial capture and detection. When developing a microarray for bacterial detection, this must be considered for optimization. For example, with the appropriate concentration of antibody (in this study, 0.125 ng/nL), spots with increased diameter at the point of contact printing (and almost no streaking) were produced, resulting in a maximal signal. With capture antibody concentrations greater than 0.125 ng/nL, the excess biotinylated capture antibody (i.e., that which was residing in the three-dimensional, semisolid droplet space above the surface) was utilized to capture more bacteria. Similarly, when the immunoassay was performed within a hydrophobic barrier (i.e., without a coverslip), brighter spots with increased signal were observed. In addition, when higher concentrations of cells (∼10(8) cells/mL) were available for capture, the importance of unbound capture antibody in the semisolid droplets became apparent because washing off the excess, unbound biotinylated capture antibody before the immunoassay was performed reduced the signal intensity by nearly 50%. This reduction in signal was not observed with lower concentrations of cells (∼10(6) cells/mL). With increased volumes of capture antibody, abnormal spots were visualized, along with decreased signal intensity, after bacterial detection, indicating that the increased droplet volume detrimentally affected the immunoassay.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and optimization of an antibody array method for potential cancer biomarker detection☆

Biomarkers play an important role in the detection at an early stage of pancreatic cancer. The aim of the present study was to optimize the conditions of antibody arrays for detecting Hippocalcin-like 1 (HPCAL1), phosphatidylethanolamine binding protein 1 (PEBP1), lectin galactoside-binding soluble 7 (LGALS7), and serpin peptidase inhibitor clade E member 2 (SERPINE2) as biomarkers for pancreat...

متن کامل

An Efficient Covalent Coating on Glass Slides for Preparation of Optical Oligonucleotide Microarrays

Objective(s): Microarrays are potential analyzing tools for genomics and proteomics researches, which is in needed of suitable substrate for coating and also hybridization of biomolecules.   Materials and Methods: In this research, a thin film of oxidized agarose was prepared on the glass slides which previously coated with poly-L-lysine (PLL). Some of the aldehyde groups of the activated aga...

متن کامل

Strong and oriented immobilization of single domain antibodies from crude bacterial lysates for high-throughput compatible cost-effective antibody array generation.

Antibody microarrays are among the novel class of rapidly emerging proteomic technologies that will allow us to efficiently perform specific diagnoses and proteomic analysis. Recombinant antibody fragments are especially suited for this approach but their stability is often a limiting factor. Camelids produce functional antibodies devoid of light chains (HCAbs) of which the single N-terminal do...

متن کامل

Composite surface for blocking bacterial adsorption on protein biochips.

The design and fabrication of protein biochips requires characterization of blocking agents that minimize nonspecific binding of proteins or organisms. Nonspecific adsorption of Escherichia coli, Listeria innocua, and Listeria monocytogenes is prevented by bovine serum albumin (BSA) or biotinylated BSA adsorbed on SiO(2) surfaces of a biochip that had been modified with a C(18) coating. Biotiny...

متن کامل

Protein microarrays on hybrid polymeric thin films prepared by self-assembly of polyelectrolytes for multiple-protein immunoassays.

We report here the development and characterization of protein microarrays fabricated on nanoengineered 3-D polyelectrolyte thin films (PET) deposited on glass slide by consecutive adsorption of polyelectrolytes via self-assembly technique. Antibodies or antigens were immobilized in the PET-coated glass slides by electrostatic adsorption and entrapment of porous structure of the 3-D polymer fil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2009