The Freedom SOLO valve: superior hemodynamic results with a new stentless pericardial valve for aortic valve replacement.

نویسندگان

  • Sven Beholz
  • Simon Dushe
  • Wolfgang Konertz
چکیده

BACKGROUND AND AIM OF THE STUDY The new Freedom SOLO aortic valve, as a modification of the Pericarbon Freedom stentless valve, requires only one suture line. The study aim was to compare both prostheses with regard to surgical convenience and early postoperative hemodynamics. METHODS In this case-matched study, 90 patients underwent primary elective isolated or combined aortic valve replacement (AVR) between 2001 and 2004. The Freedom SOLO valve was implanted in 30 patients using a supra-annular, subcoronary technique with one continuous subcoronary suture line (group FS). For comparison, the Pericarbon Freedom valve was implanted in 30 patients using an interrupted suture (group PFI), and in 30 patients using a continuous suture line at the inflow site (group PFC). Patient hemodynamics at discharge were investigated by monitoring echocardiographic peak and mean gradients, and regurgitation. RESULTS The mean extracorporeal circulation time (75.5+/-22.7 min in FS; 83.7+/-21.0 min in PFC versus 110.9+/-31.4 min in PFI) and cross-clamp time (56.0+/-18.6 min in FS; 62.2+/-16.2 min in PFC versus 87.7 +/-25.4 min in PFI) were significantly shorter with the continuous implantation techniques. Hemodynamics were most favorable for the Freedom SOLO valve as compared to either implantation technique of the Pericarbon Freedom valve (mean gradient 7.4+/-4.6 mmHg in FS versus 10.6+/-6.0 mmHg in PFC and 11.0+/-5.7 mmHg in PFI). There were no paravalvular leakages or transvalvular regurgitations. CONCLUSION The Freedom SOLO stentless valve is easy to implant and demonstrates superior early postoperative hemodynamics. Due to the reduced cross-clamp time, it also offers an attractive option in isolated and combined AVR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Operative technique and early hemodynamic results with the Freedom Solo valve.

BACKGROUND AND AIM OF THE STUDY Stentless aortic valve prostheses usually require two separate suture lines. The Freedom Solo valve (Sorin Group, Saluggia, Italy), by using a minimized implantation technique, requires only a single running suture line of 4-0 polypropylene. Herein are reported the surgical experience and early hemodynamic results obtained with this new valve. METHODS Following...

متن کامل

The Freedom SOLO bovine pericardial stentless valve: Single-center experience, outcome and long-term durability

OBJECTIVES: We report our institutional experience and long-term results with the Sorin Freedom SOLO bovine pericardial stentless bioprosthesis. METHODS: Between January 2005 and November 2009, 149 patients (mean age 73.6±8.7 years, 68 [45.6%] female) underwent isolated (n=75) or combined (n=74) aortic valve replacement (AVR) using the SOLO in our institution. Follow-up was 100% complete with a...

متن کامل

Stentless aortic valve replacement: an update

Although porcine aortic valves or pericardial tissue mounted on a stent have made implantation techniques easier, these valves sacrifice orifice area and increase stress at the attachment of the stent, which causes primary tissue failure. Optimizing hemodynamics to prevent patient-prosthetic mismatch and improve durability, stentless bioprostheses use was revived in the early 1990s. The purpose...

متن کامل

Outcomes and hemodynamics after aortic valve replacement: a comparison of stentless versus mechanical valves.

PURPOSE Some investigators suggest that hemodynamic outcomes may be superior with the stentless aortic bioprosthesis when compared with a mechanical valve. The goal of this study was to characterize outcomes and hemodynamic data associated with each type of valve. SUBJECTS AND METHODS Patient outcomes and echocardiographic data were compared between 25 patients with stentless valves and 59 pa...

متن کامل

The Sorin Freedom SOLO stentless aortic valve: easier implantation technique with potentially less risk of complications.

Aortic valve replacement by bioprosthesis is increasingly being used. Among these, stentless bioprosthesis is becoming a valid choice due to its potential hemodynamic improvement. The Sorin Freedom SOLO stentless aortic valve (FS) (Sorin Biomedica Cardio, Saluggia, Italy) is widely used, with initial and midterm promising results. It is designed to be deployed in a straightforward manner in the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of heart valve disease

دوره 16 1  شماره 

صفحات  -

تاریخ انتشار 2007