Lowering the cut off value of an automated chlamydia enzyme immunoassay and confirmation by PCR and direct immunofluorescent antibody test.
نویسندگان
چکیده
AIMS To increase the sensitivity of an automated chlamydia enzyme immunoassay by significantly lowering its cut off value, and to maintain specificity by confirmation with polymerase chain reaction (PCR) and direct immunofluorescent antibody test (DFA). METHODS Over five months, the cut off value of the enzyme immunoassay used to screen urogenital samples for chlamydia antigen was reduced from 80 to 10. Samples with a test value of 10 or above were further tested with a commercial PCR assay. All samples during the first three months and discrepant samples during the last two months of the study were also tested with the DFA. RESULTS 3250 urogenital swabs (1246 urethral, 1335 endocervical, 669 pooled urethral/endocervical) from 1246 males and 2004 females were processed. Using the manufacturer's recommended cut off of 80, the enzyme immunoassay identified chlamydia antigen in 134 samples (4.1%). Using the lower cut off value of 10 and either PCR or DFA as the confirmatory test, Chlamydia trachomatis was identified in 178 samples (5.5%). Thus, 45 additional positive samples were identified and the confirmed detection rate was increased by 33.8% (45/133). Excluding equivocal PCR results, the concordance between DFA and PCR was 91.8%. This strategy increased the detection rate by 2.1% in men and 0.9% in women (significant only in men). In female patients, pooled urethral/endocervical swabs as a specimen gave a significantly higher yield than endocervical swabs regardless of whether the lower cut off strategy was used. CONCLUSIONS This strategy of significantly lowering the cut off test value with confirmation on the same specimen by either PCR or DFA is feasible and cost effective. The use of pooled urethral/ endocervical specimens in females should be considered routinely as detection rate was significantly improved.
منابع مشابه
Use of sequential enzyme immunoassay and direct fluorescent antibody tests for detection of Chlamydia trachomatis infections in women.
Endocervical infections due to Chlamydia trachomatis remain difficult to diagnose due to the lack of an inexpensive, rapid, and accurate test. We evaluated an alternative strategy for diagnosis in which initial screening was performed with an enzyme immunoassay (Chlamydiazyme) followed by a direct fluorescent antibody (DFA) test on specimens in which the Chlamydiazyme optical density (OD) readi...
متن کاملCloning, Expression and Purification of Truncated Chlamydia Trachomatis Outer Membrane Protein 2 (Omp2) and its Application in an ELISA Assay
Background: Although a simple and direct method does not exist for the detection of chlamydial infections, there are situations in which reliable serological tests, with sensi-tivity related to a specific antigen, could be helpful. Objective: The aim of this study was to clone the first 1100 bp of the C. trachomatis outer membrane protein 2 (omp2) gene in order to prepare a recombinant protein ...
متن کاملEvaluation of conventional and real-time PCR assays using two targets for confirmation of results of the COBAS AMPLICOR Chlamydia trachomatis/Neisseria gonorrhoeae test for detection of Neisseria gonorrhoeae in clinical samples.
Two conventional PCR-enzyme immunoassays (PCR-EIAs) and two real-time PCR assays (LightCycler system; Roche Diagnostics) were evaluated as confirmation assays with cppB and 16S rRNA genes as targets. Of 765 male and female genitourinary and nasopharyngeal specimens positive for Neisseria gonorrhoeae in the COBAS AMPLICOR Chlamydia trachomatis/Neisseria gonorrhoeae PCR test (Roche Diagnostics), ...
متن کاملImpact of switching laboratory tests on reported trends in Chlamydia trachomatis infections.
Improvements in the sensitivity and specificity of laboratory testing methods for Chlamydia trachomatis infections in recent years have created potential problems with interpreting data on chlamydia prevalence trends. A switch to a more sensitive test can result in an increase in chlamydia positivity even with no increase in the true disease prevalence. To examine the impact of switching labora...
متن کاملHead-to-head evaluation of five chlamydia tests relative to a quality-assured culture standard.
Nucleic acid amplification tests offer superior sensitivity for the detection of Chlamydia trachomatis infection, but many laboratories still use nonamplification methods because of the lower cost and ease of use. In spite of their availability for more than a decade, few studies have directly compared the nonamplification tests. Such comparisons are still needed in addition to studies that dir...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 50 8 شماره
صفحات -
تاریخ انتشار 1997