Dose verification of helical tomotherapy intensity modulated radiation therapy planning using 2D-array ion chambers
نویسندگان
چکیده
PURPOSE To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered for the patients during treatments. MATERIALS AND METHODS A pixel-segmented ionisation chamber device, IMRT MatriXX™ and Multicube™ phantom from IBA were used on ten selected Tomotherapy IMRT/IGRT head and neck plans in this study. The combined phantom was set up to measure the dose distribution from coronal and sagittal planes. The setup of phantom was guided for verifying the correction position by pre-treatment Tomotherapy MVCT images. After the irradiation, the measured dose distributions of coronal and sagittal planes were compared with those from calculation by the planning system for cross verification. The results were evaluated by the absolute and relative doses as well as Gamma (γ) function. The feasibility of the different measuring methods was studied for this rotational treatment technique. RESULTS The dose distributions measured by the MatriXX 2D array were in good agreements with plans calculated by Tomotherapy planning system. The discrepancy between the measured dose and predicted dose in the selected points was within ±3%. In the comparison of the pixel-segmented ionisation chamber versus treatment planning system using the 3 mm/3% γ-function criteria, the mean passing rates of 2 mm dose grid with γ-parameter ≤1 were 97.37% and 96.91%, in two orthogonal planes (coronal and sagittal directions), respectively. CONCLUSION MatriXX with Multicube is a new system created for rotational delivery quality assurance (QA) and found to be reliable to measure both absolute dose and relative dose distributions, simultaneously. It achieves the goal of an efficient and accurate dosimetry validation method of the helical delivery pattern for the Helical Tomotherapy IMRT planning.
منابع مشابه
The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy
Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...
متن کاملDosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملOn-line quality assurance of rotational radiotherapy treatment delivery by means of a 2D ion chamber array and the Octavius phantom.
For routine pretreatment verification of innovative treatment techniques such as (intensity modulated) dynamic arc therapy and helical TomoTherapy, an on-line and reliable method would be highly desirable. The present solution proposed by TomoTherapy, Inc. (Madison, WI) relies on film dosimetry in combination with up to two simultaneous ion chamber point dose measurements. A new method is propo...
متن کاملFast, simple, and informative patient-specific dose verification method for intensity modulated total marrow irradiation with helical tomotherapy
BACKGROUND Patient-specific dose verification for treatment planning in helical tomotherapy is routinely performed using a homogeneous virtual water cylindrical phantom of 30 cm diameter and 18 cm length (Cheese phantom). Because of this small length, treatment with total marrow irradiation (TMI) requires multiple deliveries of the dose verification procedures to cover a wide range of the targe...
متن کاملAn Overview on the Clinical Application of Radiobiological Modeling in Radiation Therapy of Cancer
Submit Manuscript | http://medcraveonline.com Abbreviations: TCP: Tumor Control Probability; NTCP: Normal Tissue Control Probability; LKB: Lyman Kutcher Burman; IGRT: Image Guided Radiation Therapy; IMRT: Intensity Modulated Radiation Therapy; SIB-IMRT: Simultaneous Integrated BoostIMRT; VMAT: Volumetric Modulated Arc Therapy; DA: Double Arc; SA: Single Arc; HT: Helical Tomotherapy; IFP: Improv...
متن کامل