Head-to-cloaca electrical stunning of broilers.
نویسندگان
چکیده
This study was performed to identify the electrical current and exposure duration that would instantaneously render broiler chickens unconscious at slaughter when using a head-to-cloaca water bath stunner. The water in which the head was immersed was one electrode, and a steel-coned or cutaneous U-shaped electrode penetrating the cloaca was the other electrode. When an electrode penetrating the cloaca was used, a 640-Hz sinusoidal current induced a tonic-clonic phase on the electroencephalogram that lasted for 10 +/- 3 s and an exhaustion phase that lasted for 34 +/- 12 s. The heart rate was 375 +/- 39 beats/min before stunning. After stunning, the electrocardiogram revealed fibrillating for 429 +/- 58 s, after which the heart activity stopped. When a U-shaped electrode was placed on the skin at the cloaca, the same phenomenon was induced. A general epileptiform insult was induced when using a pulsed alternating square wave current of 33 mA (peak 60 V, 600 Hz, and a duty cycle of 50%), which lasted, on average, for 25 s (n = 25). When the broilers were bled within 14 s after stunning, they remained unconscious and the heart activity stopped after 237 +/- 103 s. We concluded from this experiment that broilers were effectively stunned with an average current of 111 mA (50 V, 640 Hz, sinusoidal alternating current) for 1 s when using a water bath in which the head of the broiler was immersed in water, with the water being one electrode and a steel electrode penetrating the cloaca or placed around it being the other electrode. Energy use could be reduced when an alternating pulsed square wave is used when the broilers are stunned, by using a current of approximately 33 mA (peak of 60 V, frequency of 600 Hz, and a 50% duty cycle).
منابع مشابه
Assessment of the effectiveness of head only and back-of-the-head electrical stunning of chickens
The study assesses the effectiveness of reversible head-only and back-of-the-head electrical stunning of chickens using 130-950 mA per bird at 50 Hz AC. Three trials were conducted to compare both stunning systems: (a) behavioural assessment of return of consciousness, (b) insensibility to thermal pain, and (c) assessment of return of brain activity with visually evoked potentials (VEPs). Asses...
متن کاملBody Weight, Carcass Yield, and Intestinal Contents of Broilers Having Sodium and Potassium Salts in the Drinking Water Twenty-Four Hours Before Processing
The purpose of this study was to investigate the effects of drinking water supplementation with graded increases of Na and K salts on the performance and gut contents of broilers before processing. Birds had no water, tap water, or water supplemented with sodium bicarbonate or potassium chloride in the concentrations of 0.15, 0.30, and 0.45% in the last 12 and 24 h before processing. The last 1...
متن کاملEffects of physical restraint and electrical stunning on plasma corticosterone, postmortem metabolism, and quality of broiler breast muscle.
The objective of this study was to determine the effects of physical restraint and electrical stunning on plasma corticosterone, postmortem metabolism, and quality of broiler breast muscle. Before slaughter, a total of 160 Arbor Acres broilers were randomly categorized into 2 replicate pens (80 broilers per pen) and every pen was randomly divided into 4 groups (free struggle, physical restraint...
متن کاملEffect of different electrical stunning conditions on meat quality in broilers
Electrical water bath stunning is still the dominant method in slaughtering of broilers. Usually, AC stunning is applied with a minimum current of 120 mA per bird according to the actual EU regulations for stunning of chicken. To investigate the impact of electrical stunning conditions on effectiveness of stunning more deeply in a first step various combinations of voltage, voltage frequency an...
متن کاملElectroencephalograms and physical reflexes of broilers after electrical waterbath stunning using an alternating current.
Stunning efficiency of broilers after electrical waterbath stunning with an alternating current was assessed using electroencephalograms (EEG) and physical reflexes. Four hundred eighty-nine broilers (246 males and 243 females) were stunned in an electrical waterbath with a rectangular alternating stunning current of 60, 80, 100, 120, and 150 mA and frequencies of 70, 100, 200, 400, 800, and 1,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Poultry science
دوره 87 10 شماره
صفحات -
تاریخ انتشار 2008