A total of 319 clinical isolates were compared for amikacin susceptibility by AutoBac I and Bauer-Kirby disk diffusion methods. There was an overall agreement of 98.5% between AutoBac I and Bauer-Kirby. An additional 23 strains resistant to amikacin, obtained from Bristol Laboratories, registered a 65% overall agreement. The sensitivity readings differed between the two methods for 13 organisms: 11 were minor discrepancies, intermediate by one of the two methods, and 2 were very major discrepancies, resistant by disk diffusion and susceptible by AutoBac I.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wide variability in Pseudomonas aeruginosa aminoglycoside results among seven susceptibility testing procedures.

Seven commonly used antimicrobial susceptibility testing methods were used to test the susceptibility of 150 isolates of Pseudomonas aeruginosa against gentamicin, tobramycin, amikacin, carbenicillin, and piperacillin. Results were compared with respect to the susceptibility characteristics of the population of isolates as defined by each method. Conventional methods included agar disk diffusio...

متن کامل

Methicillin-resistant Staphylococcus aureus susceptibility testing by an automated system, Autobac I.

The Autobac I system was used to evaluate the antibiotic susceptibility pattern of methicillin-resistant Staphylococcus aureus isolates. The results of the Autobac I were compared with the results of the disk diffusion method. The disk diffusion susceptibility pattern showed resistance to methicillin/oxacillin, penicillin, erythromycin, clindamycin, and kanamycin. All isolates were susceptible ...

متن کامل

Evaluation of the Autobac 1 susceptibility testing system in a clinical diagnostic laboratory.

The Autobac 1 system was compared to the disk diffusion and agar dilution methods. Overall, there was good correlation; however, certain antibiotic/bacterial combinations gave unreliable results. In particular, unreliable results were obtained against staphylococci with penicillins, aerobic gram-negative rods with cephalothin, and enterococci with cephalothin and clindamycin.

متن کامل

Methicillin - Resistant Staphylococcus aureus Susceptibility Testing by an Automated System , Autobac I TIMOTHY

The Autobac I system was used to evaluate the antibiotic susceptibility pattern of methicillin-resistant Staphylococcus aureus isolates. The results ofthe Autobac I were compared with the results of the disk diffusion method. The disk diffusion susceptibility pattern showed resistance to methicillin/oxacillin, penicillin, erythromycin, clindamycin, and kanamycin. All isolates were susceptible t...

متن کامل

Accuracy and precision of the autobac system for rapid identification of Gram-negative bacilli: a collaborative evaluation.

Gram-negative bacilli were identified within 3 to 6 h by determining susceptibility to 18 different antibacterial agents in the Autobac I system and by applying a two-stage quadratic discriminant analysis to the susceptibility patterns. The Autobac system was compared with standard reference methods for identifying glucose nonfermenters and glucose fermenters. Intralaboratory and interlaborator...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 9 3  شماره 

صفحات  -

تاریخ انتشار 1979