Biomedical Evaluation of Cortisol, Cortisone, and Corticosterone along with Testosterone and Epitestosterone Applying Micellar Electrokinetic Chromatography

نویسندگان

  • Tomasz Bączek
  • Ilona Olędzka
  • Lucyna Konieczna
  • Piotr Kowalski
  • Alina Plenis
چکیده

The validated micellar electrokinetic chromatography (MEKC) was proposed for the determination of five steroid hormones in human urine samples. That technique allowed for the separation and quantification of cortisol, cortisone, corticosterone, testosterone, and epitestosterone and was sensitive enough to detect low concentrations of these searched steroids in urine samples at the range of 2-300 ng/mL. The proposed MEKC technique with solid-phase extraction (SPE) procedure was simple, rapid, and has been successfully applied as a routine procedure to analyze steroids in human urine samples. The MEKC method offered a potential in clinical routine practice because of the short analysis time (8 min), low costs, and simultaneous analysis of five endogenous hormones. Due to its simplicity, speed, accuracy, and high recovery, the proposed method could offer a tool to determine steroid hormones as potential biomarkers in biomedical investigations, what was additionally revealed with healthy volunteers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of corticosterone and 17-hydroxycorticosterone in plasma and urine samples by sweeping techniques using micellar electrokinetic chromatography.

The analysis of corticosterone in mouse blood serum (metabolic-stress experiment) and 17-hydroxycorticosterone in human urine (exercise-stress experiment) samples by means of capillary electrophoresis/UV absorbance in conjunction with online sample concentration techniques is described. The use of normal MEKC had an analyte detection limit of 7 microg/ml (S/N=3); whereas when online sample conc...

متن کامل

Modeling The Capacity Factor of Analytes in Micellar Electrokinetic Chromatography Using Computational Descriptors

       A multiple linear regression model is proposed to calculate capacity factor of  analytes using structural features computed using HyperChem software. The  chemical descriptors of analytes were computed using HyperChem software and  regressed against the experimental capacity factors of analytes collected from the  literature. The absolute average percentage deviation (AARD) and individua...

متن کامل

Method development for cortisol and cortisone by micellar liquid chromatography using sodium dodecyl sulphate: application to urine samples of rugby players.

The chromatographic behavior of cortisol and cortisone using a micellar medium of sodium dodecyl sulphate (SDS) as surfactant, a Hypersil C18 (150- x 3.2-mm i.d., 5 microm) column, a flow rate of 0.5 mL/min, and UV absorbance detection at 245 nm is described. The effect of several organic modifiers and the surfactant concentration on the separation is studied. A mobile phase of 18 mM SDS and 8....

متن کامل

Comparison of the use of anionic and cationic surfactants for the separation of steroids based on MEKC and sweeping-MEKC modes.

In attempts to improve the selectivity and sensitivity of steroid separation and to determine their migration order, a comparison of the use of anionic and cationic surfactants based on the MEKC and sweeping-MEKC modes was made. A mixture of six steroids (progesterone, 17-hydroxy progesterone, 11-deoxycortisol, corticosterone, cortisone, and cortisol) could be separated and detected by means of...

متن کامل

Chemometric evaluation of urinary steroid hormone levels as potential biomarkers of neuroendocrine tumors.

Neuroendocrine tumors (NETs) are uncommon tumors which can secrete specific hormone products such as peptides, biogenic amines and hormones. So far, the diagnosis of NETs has been difficult because most NET markers are not specific for a given tumor and none of the NET markers can be used to fulfil the criteria of high specificity and high sensitivity for the screening procedure. However, by co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012