The InFOCμS Hard X-ray Telescope: Pixellated CZT Detector/Shield Performance and Flight Results

نویسندگان

  • Wayne H. Baumgartner
  • K. Tamura
چکیده

The CZT detector on the InFOCμS hard X-ray telescope is a pixellated solid-state device capable of imaging spectroscopy by measuring the position and energy of each incoming photon. The detector sits at the focal point of an 8m focal length multilayered grazing incidence X-ray mirror which has significant effective area between 20–40 keV. The detector has an energy resolution of 4.0 keV at 32 keV, and the InFOCμS telescope has an angular resolution of 2.2 arcminute and a field of view of about 10 arcminutes. InFOCμS flew on a balloon mission in July 2001 and observed Cygnus X-1. We present results from laboratory testing of the detector to measure the uniformity of response across the detector, to determine the spectral resolution, and to perform a simple noise decomposition. We also present a hard X-ray spectrum and image of Cygnus X-1, and measurements of the hard X-ray CZT background obtained with the SWIN detector on InFOCμS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Construction and Testing of a Pixellated CZT Detector and Shield for a Hard X-ray Astronomy Balloon Flight

We report on the construction and laboratory testing of pixellated CZT detectors mounted in a flip-chip, tiled fashion and read out by an ASIC, as required for proposed hard X-ray astronomy missions. Two 10 mm × 10 mm × 5 mm detectors were fabricated, one out of standard eV Products high-pressure Bridgman CZT and one out of IMARAD horizontal Bridgman CZT. Each was fashioned with a 4 × 4 array o...

متن کامل

Design and Testing of a Prototype Pixellated CZT Detector and Shield for Hard X-Ray Astronomy

We report on the design and laboratory testing of a prototype imaging CZT detector intended for balloon flight testing in April 2000. The detector tests several key techniques needed for the construction of large-area CZT arrays, as required for proposed hard X-ray astronomy missions. Two 10 mm × 10 mm × 5 mm CZT detectors, each with a 4 × 4 array of 1.9 mm pixels on a 2.5 mm pitch, will be mou...

متن کامل

CZT in Space Based Hard X-ray Astronomy: Background Predictions for EXIST

One of the key aspects of a detector material for space-borne hard X-ray and gamma-ray telescopes is the rate of prompt and delayed background events generated inside the material by charged and neutral particles striking the detector. These particles are Cosmic Rays, particles trapped in Earth’s magnetic field, and secondaries from Cosmic Ray interacting with the atmosphere and the spacecraft....

متن کامل

Balloon-borne Hard X-ray Imaging and Future Surveys

Several payloads for hard X-ray (20-600 keV) imaging with coded aperture telescopes have been developed for balloon flight observations of cosmic x-ray sources. We briefly review the characteristics of these, particularly the EXITE2 system. The recent NASA program to develop an extended long duration (100d) balloon flight capability employing super-pressure balloons would allow a qualitatively ...

متن کامل

The Cadmium Zinc Telluride (CZT) Detector Array Innovation Pathway

This pathway describes the development of soft gamma-ray/hard x-ray detector arrays at NASA’s Goddard Space Flight Center (GSFC, or Goddard), through a collaboration between the gamma-ray spectroscopy group and the detector branch. The Cadmium Zinc Telluride (CdZnTe, or CZT) detectors which resulted from this decade-long development were first flown on the wildly successful SWIFT mission in 200...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002