Fabrication and in vitro Biocompatibility of Flexible Polyimide-Based Microelectrode Array for Visual Prosthesis

نویسندگان

  • X. Sui
  • Y. Xie
  • Y. Li
  • T. Liang
  • G. Li
  • G. Zhou
  • Q. Ren
چکیده

Purpose: To make sure the biocompatibility and to get the permission to use the EPIRET3-device in a clinical trial according to German laws and to European ISO standards. To characterize the systems and the interaction with the retinal cells of RP-subjects after explantation. Methods: We tested the finally designed wireless epiretinal implants preclinically in vitro. The systems were directly seeded with murine L929 fibroblast cells. Stainings for testing the integrity of the cell membranes were perfomed. Indirect tests were used to detect potentially toxical substances in the cell suspension. After implantation in 6 RP-subjects, the system remained for 28 days. Explantation was done, and the electrode devices were characterized using scanning electron microscopy (SEM/REM). Results: The finally designed systems showed no signs of toxicity in the direct cell tests and in the indirect tests of the cell suspension. After implantation, remaining and explantation of the systems we found small groups of retinal cells on the epiretinally located electrode device. The cells were mostly identified as retinal glial (Muller) cells. Conclusions: The EPIRET3-System is a biocompatible and safe retinal implant system, successfully implanted in RP-individuals, and explanted after 28 days. The short-term biocompatibility in RP-subjects was shown in our project, following studies should characterize the long-term biocompatibility of the implants. CR: B. Sellhaus, None; T. Schanze, None. Support: BMBF, Germany CT: DE/CA21/A/07/Dr.Schmidt IOL/EPI-RETIII 3010 D606 Fabrication and in vitro Biocompatibility of Flexible Polyimide-Based Microelectrode Array for Visual Prosthesis

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biocompatibility of polyimide microelectrode array for retinal stimulation

Artificial retina is aimed for the stimulation of remained retinal neurons in the patient with degenerated photoreceptors. Microelectrode arrays have been developed for this as a part of stimulator. To minimize the damage during ophthalmic surgery and to get better contact to retina, flexible polyimide, which can be fabricated based on semiconductor manufacturing, was selected as the substrate ...

متن کامل

In vitro biocompatibility of various polymer-based microelectrode arrays for retinal prosthesis.

PURPOSE The purpose of our study is to evaluate the biocompatibility of various polymers used as microelectrode arrays (MEAs) in retinal prostheses through in vitro cytotoxicity testing following a standardized METHOD METHODS Three types of polymer-based MEAs were examined: silicone-based platinum, polyimide-based gold and liquid crystal polymer (LCP)-based gold MEAs. The silicone/platinum...

متن کامل

Design and fabrication of a polyimide-based microelectrode array: application in neural recording and repeatable electrolytic lesion in rat brain.

The design and testing of a new microelectrode array, the NCTU (National Chiao Tung University) probe, was presented. Evaluation results showed it has good biocompatibility, high signal-to-noise ratio (SNR: the root mean square of background noise to the average peak-to-peak amplitude of spikes) during chronic neural recordings, and high reusability for electrolytic lesions. The probe was a fle...

متن کامل

Low-cost microelectrode array with integrated heater for extracellular recording of cardiomyocyte cultures using commercial flexible printed circuit technology

This article reports the use of commercial, flexible printed circuit technology for the fabrication of low-cost microelectrode arrays (MEAs) for recording extracellular electrical signals from cardiomyocyte cultures. A 36-electrode array has been designed and manufactured using standard, two-layer, polyimide-based flexible circuit technology, with electrode diameters of 75 and 100 m. Copper str...

متن کامل

Development of microelectrode arrays for artificial retinal implants using liquid crystal polymers.

PURPOSE To develop a liquid crystal polymer (LCP)-based, long-term implantable, retinal stimulation microelectrode array using a novel fabrication method. METHODS The fabrication process used laser micromachining and customized thermal-press bonding to produce LCP-based microelectrode arrays. To evaluate the fabrication process and the resultant electrode arrays, in vitro reliability tests an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008