Brief laboratory report: surgical drape flammability.

نویسنده

  • Jessica Goldberg
چکیده

Fires in the operating room continue to present a hazard to patients, at times with catastrophic and debilitating results. Recent data from closed claim files reveal oxygen, electrosurgical unit (ESU), and surgical drapes are common components of the fire triangle in the operating room. In this era of biotechnological sophistication, why are surgical drapes flammable? The purpose of this study was to test the flammability of different surgical drape materials and to determine the time to ignition using a bipolar ESU device in 21%, 35%, and 100% oxygen concentrations. Results show that regardless of oxygen concentration surgical drapes, when exposed to close contact with the ESU, are flammable. Time to ignition decreases with increasing concentrations of oxygen as expected. One of the surgical drapes tested was advertised to the hospital as nonflammable. Future research should focus on surgical drape materials and aim to reduce the flammability of such items in the operating room.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel radiation protection drape reduces radiation exposure during fluoroscopy guided electrophysiology procedures.

OBJECTIVE The purpose of this study was to evaluate a novel disposable lead-free radiation protection drape for decreasing radiation scatter during electrophysiology procedures. BACKGROUND In recent years, there has been an exponential increase in the number of electrophysiology (EP) procedures exposing patients, operators and laboratory staff to higher radiation doses. METHODS The RADPAD w...

متن کامل

Interference between surgical magnetic drapes and pacemakers: an observational study comparing commercially available devices and a new magnetically isolated drape

BACKGROUND Magnetic fields may potentially interfere with the function of cardiovascular implantable electronic devices. Sterile magnetic drapes used to hold surgical instruments are often placed on the patient's thorax, and they are likely to interfere with the function of these devices. METHODS Thirty patients were recruited to compare a new prototype surgical magnetic drape (LT10G™ by Meno...

متن کامل

Surgical Adhesive Drape (IO-ban) as Postoperative Surgical Site Dressing.

STUDY DESIGN Retrospective chart analysis. OBJECTIVE The objective of this study is to describe the senior author's (MNN) experience applying a widely available surgical drape as a postoperative sterile surgical site dressing for both cranial and spinal procedures. SUMMARY OF BACKGROUND DATA Surgical site infection (SSI) is an important complication of spine surgery that can result in signi...

متن کامل

Antimicrobial activity and skin permeation of iodine present in an iodine-impregnated surgical incise drape.

OBJECTIVES The antimicrobial efficacy of an iodine-impregnated incise drape against MRSA was evaluated in a skin model. The permeation of iodine from this drape into the skin was also assessed. METHODS The antimicrobial efficacy was evaluated in ex vivo studies following application of the surgical incise drape for various times on the surface of donor skin, which was inoculated with either 1...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AANA journal

دوره 74 5  شماره 

صفحات  -

تاریخ انتشار 2006