Incompatible amount of 3-D and 2-D periodontal attachments on micro-CT scanned premolars

نویسندگان

  • Hsiang-Hsi Hong
  • Adrienne Hong
  • Yi-Fang Huang
  • Heng-Liang Liu
چکیده

Micro-computed tomography (micro-CT) was employed to relate the root surface area (RSA) to the periodontal attachment levels (PALs) of extracted premolars to diagnose periodontitis. Single-rooted human maxillary and mandibular premolars 31 and 36, respectively, were surveyed by micro-CT and its associated software. RSA levels from the 1st to 10th mm, corono-apically, were analyzed using statistical t tests. The average root length (RL) and RSA of the maxillary and mandibular premolars were significantly different (p < 0.05). Both premolars demonstrated a non-significant RSA percentage comparison at the evaluated PALs. For the 30% coronal 2-D radiographic RL, the 3-D RSAs 3.77 mm and 3.99 mm apical to the cementoenamel junction (CEJ) were 39.48% and 40.65% for maxillary and mandibular premolars, respectively. At the 15% coronal 2-D RL, the 3-D RSA 2 mm apical to the CEJ of the premolars was approximately 21%. At the 50% coronal 2-D RL level, approximately 62% coronal 3-D RSA and 6.5 mm RL decreased. The amount of decrease of the RSA attachment is significant in every 2-mm measurement for both premolars. Sampling periodontal microbial pathogens based on the condition of 2-D radiographic bone and clinical attachment losses without considering 3-D RSA is potentially inadequate and may underestimate the severity of the periodontitis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of preparation techniques on root canal shaping assessed by micro-computed tomography

BACKGROUND Root canal shaping without any procedural error is of the utmost preference. Therefore, the purpose of this study was to use micro-computed tomography to evaluate and compare the root canal shaping efficacy of ProTaper rotary files and standard stainless steel K-files. MATERIAL AND METHODS Sixty extracted upper second premolars were selected and were divided into 2 groups of 30. Be...

متن کامل

Three-dimensional micro-computed tomographic imaging of alveolar bone in experimental bone loss or repair.

BACKGROUND Micro-computed tomography (micro-CT) offers significant potential for identifying mineralized structures. However, three-dimensional (3-D) micro-CT of alveolar bone has not been adapted readily for quantification. Moreover, conventional methods are not highly sensitive for analyzing bone loss or bone gain following periodontal disease or reconstructive therapy. The objective of this ...

متن کامل

Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures

Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...

متن کامل

Conjoined Twin

:HSUHVHQWDFRQMRLQHGWZLQ &7FDVHRISUHJQDQF LQ D HDUROG ZRPDQ JUDYLGD SDUD ZKRFDPH IRUKHU¿UVW URXWLQHXOWUDVRXQGDW ZHHNVRIJHVWDWLRQ6KHFRQFHLYHGEVSRQWDQHRXV conception. The patient had a healthy child from a SUHYLRXVSUHJQDQF7KHLQLWLDOXOWUDVRXQGUHYHDOHG two fetuses with a fused thorax and abdomen, two spines with an unusual extension, one beating heart, VKDUHG OLYHU DFURVV WKH IHWXVHV IRXU NLGQHV W...

متن کامل

Investigating the effects of different kernels used for CT image reconstruction on dose distributions in treatment planning of kidney cancer radiotherapy

Introduction: The quality of CT images used for treatment planning of cancer patients is an important issue in accurate outlining of the tumor volume and organs at risk. Different kernels in CT scanner systems are available for improving the image quality. Applying these kernels  on   CT  images  will  change   the   CT  numbers  and  electron   density   of   tissues, conse...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2018