A Fast and in-Situ Measuring Method Using Laser Triangulation Sensors for the Parameters of the Connecting Rod
نویسندگان
چکیده
The connecting rod is a critical part inside the marine engine. The inspection of its important parameters is directly related to the assembly and quality of the marine engine. A coordinate measuring machine (CMM) is a conventional choice to measure the parameters of a connecting rod. However, CMM requires significant resources in time and cost, which leads researchers into in-situ measurement. This article presents a fast and in-situ measuring method by using a laser-based measuring head. Two measuring strategies are adopted in the inspection process. For positional measurements (such as the hole-center distance), whose accuracy requirement is generally low, the coordinate system of the numerical control (NC) machine is combined with the measuring head to acquire the positional parameters. For dimensional measurements (such as inner diameters), whose accuracy requirement is rather high, the NC machine is used just as transportation. Note that the measuring head has the ability to perform the dimension inspection independently. The accuracy of the measuring head is high enough to meet the dimensional accuracy requirements. Experiments are performed to validate the proposed method. The measuring error of the inner diameters is from 5 μm to 7 μm. The measuring error of hole-center distance is within 15 μm. The measurement of all these parameters can be done within 1 min.
منابع مشابه
Study and Simulation of Shot peening Effect on Fatigue Life of a Powder Forged Connecting rod
Shot peening applies a residual compressive stress field (RCSF) on the surface of parts. It also shifts “crack nucleation sites” to sub-surface locations. A nondestructive method of measuring the stresses, Sin2ψ was utilized here and the stress values introduced to Ansys software. For this purpose, uniform stress in all directions was applied on the con rod. Loading on the rod in Ansys had thre...
متن کاملA Fast Measuring Method for the Inner Diameter of Coaxial Holes
A new method for fast diameter measurement of coaxial holes is studied. The paper describes a multi-layer measuring rod that installs a single laser displacement sensor (LDS) on each layer. This method is easy to implement by rotating the measuring rod, and immune from detecting the measuring rod's rotation angles, so all diameters of coaxial holes can be calculated by sensors' values. While re...
متن کاملModelling and Calibration Technique of Laser Triangulation Sensors for Integration in Robot Arms and Articulated Arm Coordinate Measuring Machines
A technique for intrinsic and extrinsic calibration of a laser triangulation sensor (LTS) integrated in an articulated arm coordinate measuring machine (AACMM) is presented in this paper. After applying a novel approach to the AACMM kinematic parameter identification problem, by means of a single calibration gauge object, a one-step calibration method to obtain both intrinsic-laser plane, CCD s...
متن کاملThe Milling of Metalsthrough Adaptive Neuro-FuzzyInference System (ANFIS) for non-touch Measuring of the Temperature to Reduce Coolant
In this paper, an innovated method is used for cooling Milling zone of Stainless Steel via Adaptive Neuro-Fuzzy Inference System (ANFIS) using non-touch laser thermometer for non-touch measuring of the temperature. This method is economically appropriate because of its optimization in using coolant. In comparison to the ways which were designed to optimize the ratio of coolant, this method is t...
متن کاملIn-situ preconcentration, and electrochemical sensing of zinc(II) and copper(II) based on ionic liquid mediated hollow fiber-modified pencil graphite electrode using response surface methodology
A single-use electrochemical sensor using ionic liquid mediated hollow fiber-graphite working electrode was fabricated for the first time. The screening tool was developed by coupling this electrode with differential pulse voltammetry (DPV) for in-situ pre-concentration and determination of Zn(II) and Cu(II). In our plot, porous polypropylene hollow fiber membrane was divided into pieces of 2 c...
متن کامل