Analytical model to describe fluorescence spectra of normal and preneoplastic epithelial tissue: comparison with Monte Carlo simulations and clinical measurements.
نویسندگان
چکیده
Fluorescence spectroscopy has shown promise for the detection of precancerous changes in vivo. The epithelial and stromal layers of tissue have very different optical properties; the albedo is relatively low in the epithelium and approaches one in the stroma. As precancer develops, the optical properties of the epithelium and stroma are altered in markedly different ways: epithelial scattering and fluorescence increase, and stromal scattering and fluorescence decrease. We present an analytical model of the fluorescence spectrum of a two-layer medium such as epithelial tissue. Our hypothesis is that accounting for the two different tissue layers will provide increased diagnostic information when used to analyze tissue fluorescence spectra measured in vivo. The Beer-Lambert law is used to describe light propagation in the epithelial layer, while light propagation in the highly scattering stromal layer is described with diffusion theory. Predictions of the analytical model are compared to results from Monte Carlo simulations of light propagation under a range of optical properties reported for normal and precancerous epithelial tissue. In all cases, the mean square error between the Monte Carlo simulations and the analytical model are within 15%. Finally, model predictions are compared to fluorescence spectra of normal and precancerous cervical tissue measured in vivo; the lineshape of fluorescence agrees well in both cases, and the decrease in fluorescence intensity from normal to precancerous tissue is correctly predicted to within 5%. Future work will explore the use of this model to extract information about changes in epithelial and stromal optical properties from clinical measurements and the diagnostic value of these parameters.
منابع مشابه
Comparison of dosimetry parameters of two commercially available Iodine brachytherapy seeds using Monte Carlo calculations
Background: Iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. Dosimetric parameters of brachytherapy sources should be determined according to AAPM TG-43U1 recommendations before clinical use. Monte Carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. Materials and Methods: Dosimetric param...
متن کاملUnderstanding the contributions of NADH and collagen to cervical tissue fluorescence spectra: modeling, measurements, and implications.
OBJECTIVE At 380 nm excitation, cervical tissue fluorescence spectra demonstrate characteristic changes with both patient age and the presence of dysplasia. A Monte Carlo model was developed in order to quantitatively examine how intrinsic NADH and collagen fluorescence, in combination with tissue scattering and absorption properties, yield measured tissue spectra. METHODS Excitation-emission...
متن کاملComparison of measured and Monte Carlo calculated dose distributions from “circular collimators” for radiosurgical beams
Background: Stereotactic radiosurgery is an important clinical tool for the treatment of small lesions in the brain, including benign conditions, malignant and localized metastatic tumors. A dosimetry study was performed for Elekta ‘Synergy S ’ as a dedicated Stereotactic radiosurgery unit, capable of generating circular radiation fields with diameters of 1-5 cm at isocentre using the BEAM/EGS4...
متن کاملDevelopement a simple point source model for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code
Background: Monte Carlo (MC) modeling of a linear accelerator is a prerequisite for Monte Carlo dose calculations in external beam radiotherapy. In this study, a simple and efficient model was developed for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code Materials and methods: The head of Elekta SL-25 linac was simulated for 6 and 18 MV photon beams using MCNP4C MC code. Energ...
متن کاملBenchmarking of Monte Carlo model of 6 Mv photon beam produced by Siemens Oncor® linear accelerator: determination of initial electron beam parameters in comparison with measurement
Introduction: The aim of this study was to investigate the initial electron beam parameters for Monte Carlo model of 6MV photon beam produced by Siemens Oncor® linear accelerator. Materials and Methods: In this study, the EGSnrc Monte Carlo user codes BEAMnrc and DOSXYZnrc were used. The beamnrc code were used for modelling of a 6 MV photon beam produced by...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical optics
دوره 9 3 شماره
صفحات -
تاریخ انتشار 2004