Protein-protein interaction analysis in single microfluidic droplets using FRET and fluorescence lifetime detection.
نویسندگان
چکیده
Herein, we demonstrate the feasibility of a protein-protein interaction analysis and reaction progress monitoring in microfluidic droplets using FRET and microscopic fluorescence lifetime measurements. The fabrication of microdroplet chips using soft- and photolithographic techniques is demonstrated and the resulting chips reliably generate microdroplets of 630 pL and 6.71 nL at frequencies of 7.9 and 0.75 Hz, respectively. They were used for detection of protein-protein interactions in microdroplets using a model system of Alexa Fluor 488 labelled biotinylated BSA, Alexa Fluor 594 labelled streptavidin and unlabelled chicken egg white avidin. These microchips could be used for quantitative detection of avidin and streptavidin in microdroplets in direct and competitive assay formats with nanomolar detection limits, corresponding to attomole protein amounts. Four droplets were found to be sufficient for analytical determination. Fluorescence intensity ratio and fluorescence lifetime measurements were performed and compared for microdroplet FRET determination. A competitive on-chip binding assay for determination of unlabelled avidin using fluorescence lifetime detection could be performed within 135 s only.
منابع مشابه
Single Cell FRET Analysis for the Identification of Optimal FRET-Pairs in Bacillus subtilis Using a Prototype MEM-FLIM System
Protein-protein interactions can be studied in vitro, e.g. with bacterial or yeast two-hybrid systems or surface plasmon resonance. In contrast to in vitro techniques, in vivo studies of protein-protein interactions allow examination of spatial and temporal behavior of such interactions in their native environment. One approach to study protein-protein interactions in vivo is via Förster Resona...
متن کاملScreening for protein-protein interactions using Förster resonance energy transfer (FRET) and fluorescence lifetime imaging microscopy (FLIM)
We present a high content multiwell plate cell-based assay approach to quantify protein interactions directly in cells using Förster resonance energy transfer (FRET) read out by automated fluorescence lifetime imaging (FLIM). Automated FLIM is implemented using wide-field time-gated detection, typically requiring only 10 s per field of view (FOV). Averaging over biological, thermal and shot noi...
متن کاملA method to quantify FRET stoichiometry with phasor plot analysis and acceptor lifetime ingrowth.
FRET is widely used for the study of protein-protein interactions in biological samples. However, it is difficult to quantify both the FRET efficiency (E) and the affinity (Kd) of the molecular interaction from intermolecular FRET signals in samples of unknown stoichiometry. Here, we present a method for the simultaneous quantification of the complete set of interaction parameters, including fr...
متن کاملSensitive Detection of p65 Homodimers Using Red-Shifted and Fluorescent Protein-Based FRET Couples
BACKGROUND Fluorescence Resonance Energy Transfer (FRET) between the green fluorescent protein (GFP) variants CFP and YFP is widely used for the detection of protein-protein interactions. Nowadays, several monomeric red-shifted fluorescent proteins are available that potentially improve the efficiency of FRET. METHODOLOGY/PRINCIPAL FINDINGS To allow side-by-side comparison of several fluoresc...
متن کاملTime-domain fluorescence lifetime imaging microscopy: a quantitative method to follow transient protein-protein interactions in living cells.
Quantitative analysis in Förster resonance energy transfer (FRET) imaging studies of protein-protein interactions within live cells is still a challenging issue. Many cellular biology applications aim at the determination of the space and time variations of the relative amount of interacting fluorescently tagged proteins occurring in cells. This relevant quantitative parameter can be, at least ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Lab on a chip
دوره 13 14 شماره
صفحات -
تاریخ انتشار 2013