Spontaneously breathing lung model comparison of work of breathing between automatic tube compensation and pressure support.
نویسندگان
چکیده
INTRODUCTION Automatic tube compensation (ATC), a new ventilation mode that compensates for the work of breathing imposed by endotracheal tube resistance, recently became commercially available. METHODS We conducted a laboratory study with a lung model and a Nellcor Puritan Bennett 840 ventilator to compare ATC and pressure-support ventilation (PSV). A bellows-in-a-box lung model simulated spontaneous breathing with the following settings: respiratory rate 10 breaths/min, inspiratory time 1.0 s, peak inspiratory flow 60 L/min without connecting to the ventilator and endotracheal tube (ETT). At each ETT size (5, 6, 7, 8 and 9 mm inner diameter) 100% ATC was compared with pressure support (PS) of 0, 2, 4, 6, 8, and 10 cm H(2)O at positive end-expiratory pressure (PEEP) of 0 and 5 cm H(2)O. The negative deflection (PI) of the "alveolar" pressure (ie, pressure inside the bellows, P(alv)) and the delay time were measured. The PI and total pressure-time product (PTP(tot)) integrated from P(alv) were analyzed. PTP(tot) was subdivided into PTP(trig) (the PTP from the beginning of inspiration to the minimum P(alv)) and PTP(supp) (the PTP from the minimum P(alv) to the return to baseline P(alv)). RESULTS At PEEP of 0 cm H(2)O: with ETTs of 5, 6, and 7 mm the PI values with ATC corresponded to PS of 0-4 cm H(2)O; with the 8-mm ETT the PI values corresponded to PS of 0 cm H(2)O; with the 9-mm ETT the PI values corresponded to PS of 0-2 cm H(2)O. At PEEP of 5 cm H(2)O, with all ETT sizes the PI values corresponded to PS of 0 cm H(2)O. PTP(tot) and PTP(supp) of ATC corresponded to: PS of 2-4 cm H(2)O with the 5-mm ETT; PS of 2 cm H(2)O with the 6-mm ETT; PS of 0-2 cm H(2)O with the 7-mm ETT; and PS of 0 cm H(2)O with the 8- and 9-mm ETTs, at PEEP of 0 cm H(2)O. PEEP of 5 cm H(2)O was not tested for PTP. PTP(trig) with ATC showed comparable or greater values with each size of ETT. CONCLUSIONS ATC with a Nellcor Puritan Bennett 840 ventilator provided inspiratory ventilatory support corresponding to PS of <or= 4 cm H(2)O, depending on ETT size, which was not enough to compensate for the work of breathing imposed by the ETT.
منابع مشابه
Automatic tube compensation: is it worthwhile?
The influence of the endotracheal tube (ETT) during weaning has been questioned. Concerns about the work of breathing (WOB) imposed by the ETT have led to the use of various corrective methods and ventilatory modes to overcome ETT resistance. Despite the theoretical advantages of different approaches, such as pressure support (PSV) and/or automatic tube compensation (ATC), no methods appear to ...
متن کاملDoes automatic tube compensation change metabolic parameters when added to pressure support mode during weaning?
Introduction Artificial airway increases work of breathing (WOB) during weaning [1] which is one of the reasons for weaning failure [2]. Pressure support ventilation (PSV) decreases WOB and oxygen expenditure by decreasing resistance caused by artificial airway. Because inspiratory flow changes with every breath during PSV, it can not constantly compansate the changes in resistance caused by ch...
متن کاملPressure support compensation for inspiratory work due to endotracheal tubes and demand continuous positive airway pressure.
We evaluated the use of pressure support to compensate for the added inspiratory work of breathing due to the resistances of endotracheal tubes and a ventilator demand-valve system for continuous positive airway pressure (CPAP). A mechanical model was used to simulate spontaneous breathing at five respiratory rates through 7-mm, 8-mm, and 9-mm endotracheal tubes with and without a ventilator de...
متن کاملHY POXIA AND I TS INFLUEN CES ON THE CARDIOVASCULAR AND RESPIRATORY SYSTEMS OF SPONTANEOUSLY BREATHING CATS
Effects of acute systemic hypoxia on the cardiovascular system (CYS) and respiration of spontaneously breathing cats were studied in two conditions. 1): Hypoxic air (6-8% 02 in N2) was given to the animal to induce systemic hypoxia for 20 minutes. Hyperventilation at this condition lowered arterial C02 tension (PaC02 hypocapnia). 2): In the second run, induction of hypocapnia was prevented ...
متن کاملDoes the tube-compensation function of two modern mechanical ventilators provide effective work of breathing relief?
OBJECTIVE An endotracheal tube (ETT) imposes work of breathing on mechanically ventilated patients. Using a bellows-in-a-box model lung, we compared the tube compensation (TC) performances of the Nellcor Puritan-Bennett 840 ventilator and of the Dräger Evita 4 ventilator. MEASUREMENTS AND RESULTS Each ventilator was connected to the model lung. The respiratory rate of the model lung was set a...