A Multi-point Detection System with Addressable Elec- Trode Array Device Incorporated with Ida Electrodes

نویسندگان

  • K. Ino
  • W. Saito
  • M. Koide
  • T. Umemura
  • H. Shiku
  • T. Matsue
چکیده

ABSTRACT In this study, we developed a novel device consisting of 32 row and 32 column electrodes on a single chip for highthroughput electrochemical detection. The row and column electrodes were orthogonally arranged and connected to interdigitated array (IDA) electrodes at individual crossing points to form 1024 (32 × 32) sensor points. Electrochemical responses from each of the 1024 sensors were acquired using redox cycling at individual IDA electrodes. Alkaline phosphatase (ALP) activity were successfully detected using the device. The device is a high-throughput lab-on-a-chip tool for applications such as enzyme-linked immunosorbent assay (ELISA), reporter gene assay for monitoring gene expressions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Addressable Electrode Array Device Incorporated with Ida Electrodes for Biological Analyses

In the past decade, several kinds of microelectrode arrays have been applied to chemical and biological analyses. These electrochemical array devices have substantial advantages, including rapid response time and qualitative and quantitative detection. Among the various systems that are based on electrochemical detection, individually addressable electrode arrays have been used for simultaneous...

متن کامل

Droplet array on local redox cycling-based electrochemical (LRC-EC) chip device.

We have previously reported a local redox cycling-based electrochemical (LRC-EC) system for the incorporation of many electrochemical sensors into a small chip device. In the present study, a new type of LRC-EC chip device was fabricated for the detection of a droplet array. To detect electrochemically redox compounds in droplets, Pt pseudo-reference/counter electrodes were incorporated into th...

متن کامل

A high-throughput assay for evaluation of embryoid bodies using local redox cycling-based electrochemical chip device

We have previously developed a local redox cyclingbased electrochemical (LRC-EC) chip device for highthroughput electrochemical detection [1-2]. In the LRCEC chip device, row and column electrodes are arranged orthogonally and these electrodes are connected to interdigitated array (IDA) electrodes to form n crossing points with only 2n bonding pads for external connection. Local redox cycling c...

متن کامل

On-chip multi-electrochemical sensor array platform for simultaneous screening of nitric oxide and peroxynitrite.

In this work we report on the design, microfabrication and analytical performances of a new electrochemical sensor array (ESA) which allows for the first time the simultaneous amperometric detection of nitric oxide (NO) and peroxynitrite (ONOO(-)), two biologically relevant molecules. The on-chip device includes individually addressable sets of gold ultramicroelectrodes (UMEs) of 50 µm diameter...

متن کامل

Bioelectrochemical Imaging with Micro/Nanoelectrode Systems

This paper report a novel approach for bioimaging with two different micro/nanoelectrode systems; i. e., scanning electrochemical microscopy (SECM) and individually addressable microelectrode array. Hybrid SECM systems with shear-force or ion-conductance feedback distance control were applied to high resolution and simultaneous imaging of topography and electrochemical responses of enzymes and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010