Sensitivity of the Oxford Foot Model to marker misplacement: A systematic single-case investigation.
نویسندگان
چکیده
The purpose of this paper was to systematically assess the effect of Oxford Foot Model (OFM) marker misplacement on hindfoot relative to tibia, and forefoot relative to hindfoot kinematic calculations during the stance phase of gait. Marker trajectories were recorded with an 8-camera motion analysis system (Vicon Motion Systems Ltd., UK) and ground reaction forces were recorded from three force platforms (AMTI, USA). A custom built marker cluster consisting of 4 markers in a square arrangement (diagonal distance 2 cm) was used to assess the effect of marker misplacement in the superior, inferior, anterior and posterior direction for the sustentaculum tali (STL), the proximal 1st metatarsal (P1M), distal 5th metatarsal (D5M), proximal 5th metatarsal (P5M) and lateral calcaneus (LCA) markers. In addition manual movement of the heel complex 1 cm superiorly, inferiorly, medially and laterally, and also an alignment error of 10° inversion and 10° eversion was assessed. Clinically meaningful effects of marker misplacement were determined using a threshold indicating the minimal clinically important difference. Misplacement of the heel-wand complex had the most pronounced effect on mean kinematic profiles during the stance phase across all degrees-of-freedom with respect to hindfoot-tibia and forefoot-hindfoot angles. Vertical marker misplacement of the D5M and P5M markers affected the sagittal plane, and to a lesser extent frontal plane, forefoot-hindfoot kinematics. In conclusion, the OFM is highly sensitive to misplacement of the heel-wand complex in all directions and the P5M marker in the vertical direction.
منابع مشابه
A single-vendor and a single-buyer integrated inventory model with ordering cost reduction dependent on lead time
Lead time is one of the major limits that affect planning at every stage of the supply chain system. In this paper, we study a continuous review inventory model. This paper investigates the ordering cost reductions are dependent on lead time. This study addressed two-echelon supply chain problem consisting of a single vendor and a single buyer. The main contribution of this study is that the in...
متن کاملDesign and Evaluation of an Articulated Ankle Foot Orthosis with Plantarflexion Resistance on the Gait: a Case Series of 2 Patients with Hemiplegia
Ankle-foot orthoses (AFOs) have been described to have positive effects on the gait biomechanics in stroke patients. The plantarflexion resistance of an AFO is considered important for hemiplegic patients, but the evidence is still limited. The purpose of this case series was to design and evaluate the immediate effect of an articulated AFO on kinematics and kinetics of lower-limb joints in str...
متن کاملPredictive value of red blood cell distribution width for mortality in patients with acute pancreatitis: A systematic review and meta-analysis
Background: Red blood cell distribution width (RDW) is a quantitative measure of variability in the size of circulating erythrocytes. It has been recently identified as a prognostic marker in several diseases including acute pancreatitis (AP). In this systematic review the prognostic value of RDW in predicting mortality of AP patients will be assessed. Methods: PubMed, Scopus, EMBASE, and ISI ...
متن کاملIntegrated JIT Lot-Splitting Model with Setup Time Reduction for Different Delivery Policy using PSO Algorithm
This article develops an integrated JIT lot-splitting model for a single supplier and a single buyer. In this model we consider reduction of setup time, and the optimal lot size are obtained due to reduced setup time in the context of joint optimization for both buyer and supplier, under deterministic condition with a single product. Two cases are discussed: Single Delivery (SD) case, and Multi...
متن کاملQuantitative Comparison of Analytical solution and Finite Element Method for investigation of Near-Infrared Light Propagation in Brain Tissue Model
Introduction: Functional Near-Infrared Spectroscopy (fNIRS) is an imaging method in which light source and detector are installed on the head; consequently, re-emission of light from human skin contains information about cerebral hemodynamic alteration. The spatial probability distribution profile of photons penetrating tissue at a source spot, scattering into the tissue, and being released at ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Gait & posture
دوره 42 3 شماره
صفحات -
تاریخ انتشار 2015