An Ex-Vivo Study on the Shaping Parameters of Two Nickel-Titanium Rotary Systems Compared with Hand Instruments

نویسندگان

  • Maryam Ehsani
  • Samir Zahedpasha
  • Ali Akbar Moghadamnia
  • Jaber Mirjani
چکیده

UNLABELLED   INTRODUCTION Rotary nickel-titanium (NiTi) instruments are thought to allow shaping of narrow, curved root canals more efficiently and more effectively than stainless steel hand instruments. However, the continued search for even more effective and safer instruments has resulted in new rotary systems being introduced on a regular basis. The aim of this study was to compare shaping parameters of RaCe and Mtwo NiTi rotary files with stainless steel K-Flexofile hand instrument. MATERIALS AND METHODS A total of 60 mandibular first molars with 20-40 degree of curvature in mesial root were divided in to three groups and each was prepared with one kind of instrument (RaCe, Mtwo, stainless steel K-Flexofile). Using pre and post-radiographs, canal curvature was measured, with the Schneider technique. Preparation time was recorded. For evaluating canal centering and transportation, the tooth was sectioned 3, 6 and 9 mm from the apex. Pre and post- preparation photographs were taken from mesiolingual canal. Data was statistically analyzed using One-way ANOVA and Chi-Square tests. RESULTS RaCe and Mtwo maintained canal curvature better than K-Flexofile (P<0.001). Mtwo prepared the canal in a shorter time (P<0.001). CONCLUSION Significant statistical difference was not found in the three canal sections between the various systems. RaCe resulted in significantly fewer canal aberrations and better centering ability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی مشکلات آماده سازی کانال با وسائل دستی و چرخشی نیکل تیتانیوم

Background and Aim: Maintaining the original canal path and safety of canal preparation during instrumentation in curved canals have been subjected to many challenges. The aim of this study was to compare several parameters of root canal preparation using flexmaster rotary and hand used Nickel-Titanium instruments. Materials and Methods: In this experimental study, sixty extracted human teeth w...

متن کامل

Shaping ability of two M-wire and two traditional nickel-titanium instrumentation systems in S-shaped resin canals.

AIMS The aim of this study was to evaluate the shaping effects of two M-wire and two traditional nickel-titanium (NiTi) rotary systems in simulated S-shaped resin canals. SUBJECTS AND METHODS Forty simulated S-shaped canals in resin blocks were instrumented with two traditional (ProTaper, Sendoline S5) and two M-wire (WaveOne, GT series X) NiTi systems according to the manufacturers' instruct...

متن کامل

Comparative study of six rotary nickel-titanium systems and hand instrumentation for root canal preparation.

AIM To compare ex vivo various parameters of root canal preparation using a manual technique and six different rotary nickel-titanium (Ni-Ti) instruments (FlexMaster, System GT, HERO 642, K3, ProTaper, and RaCe). METHODOLOGY A total of 147 extracted mandibular molars were divided into seven groups (n = 21) with equal mean mesio-buccal root canal curvatures (up to 70 degrees), and embedded in ...

متن کامل

Comparison of the amount of apically extruded debris during retreatment using different nickel-titanium systems and hand instruments in teeth with wide apices

Objective: The purpose of this study was to compare the apically extruded debris during endodontic retreatment of teeth with open apices using hand instruments and rotary instruments with continuous rotation and reciprocation. Methodology: Forty-five single-rooted maxillary incisors and canines were used. The root tips were dissected and #1 Gates Glidden burs were allowed to protrude 1 mm beyon...

متن کامل

A Comparison of Canal-centering ability of Two Nickel-Titanium Rotary Systems with Nickel Hand Instrumentation with Stainless Steel Hand Instrumentation in 10 to 25° Curved Canals using Kuttler's Cube

AIMS The purpose of this study was to compare the canal centering abilities of rotary nickel-titanium (NiTi) files (ProFile 0.04 and 0.06 and Lightspeed LSX) and NiTi hand K-files in 10° to 25° curved canals. This was compared with the canal centering ability of stainless steel hand K-files using Kuttler's endodontic cube. SETTINGS AND DESIGN The teeth with a 10° to 25° of clinical mesiodista...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011