2D cine DENSE with low encoding frequencies accurately quantifies cardiac mechanics with improved image characteristics

نویسندگان

  • Gregory J. Wehner
  • Jonathan D. Grabau
  • Jonathan D. Suever
  • Christopher M. Haggerty
  • Linyuan Jing
  • David K. Powell
  • Sean M. Hamlet
  • Moriel H. Vandsburger
  • Xiaodong Zhong
  • Brandon K. Fornwalt
چکیده

BACKGROUND Displacement Encoding with Stimulated Echoes (DENSE) encodes displacement into the phase of the magnetic resonance signal. The encoding frequency (ke) maps the measured phase to tissue displacement while the strength of the encoding gradients affects image quality. 2D cine DENSE studies have used a ke of 0.10 cycles/mm, which is high enough to remove an artifact-generating echo from k-space, provide high sensitivity to tissue displacements, and dephase the blood pool. However, through-plane dephasing can remove the unwanted echo and dephase the blood pool without relying on high ke. Additionally, the high sensitivity comes with the costs of increased phase wrapping and intra-voxel dephasing. We hypothesized that ke below 0.10 cycles/mm can be used to improve image characteristics and provide accurate measures of cardiac mechanics. METHODS Spiral cine DENSE images were obtained for 10 healthy subjects and 10 patients with a history of heart disease on a 3 T Siemens Trio. A mid-ventricular short-axis image was acquired with different ke: 0.02, 0.04, 0.06, 0.08, and 0.10 cycles/mm. Peak twist, circumferential strain, and radial strain were compared between acquisitions employing different ke using Bland-Altman analyses and coefficients of variation. The percentage of wrapped pixels in the phase images at end-systole was calculated for each ke. The dephasing of the blood signal and signal to noise ratio (SNR) were also calculated and compared. RESULTS Negligible differences were seen in strains and twist for all ke between 0.04 and 0.10 cycles/mm. These differences were of the same magnitude as inter-test differences. Specifically, the acquisitions with 0.04 cycles/mm accurately quantified cardiac mechanics and had zero phase wrapping. Compared to 0.10 cycles/mm, the acquisitions with 0.04 cycles/mm had 9 % greater SNR and negligible differences in blood pool dephasing. CONCLUSIONS For 2D cine DENSE with through-plane dephasing, the encoding frequency can be lowered to 0.04 cycles/mm without compromising the quantification of twist or strain. The amount of wrapping can be reduced with this lower value to greatly simplify the input to unwrapping algorithms. The strain and twist results from studies using different encoding frequencies can be directly compared.

منابع مشابه

Low encoding frequencies accurately quantify cardiac mechanics while minimizing phase wrapping in 2D cine DENSE with through-plane dephasing

Background Displacement Encoding with Stimulated Echoes (DENSE) encodes displacement into the phase of the MR signal to quantify cardiac mechanics. The encoding frequency (ke) links myocardial displacement to phase. Studies with 2D cine DENSE have used ke of 0.10 cycles/mm, which is high enough to remove the stimulated anti-echo from the sampled k-space and is partially responsible for dephasin...

متن کامل

Accelerated two-dimensional cine DENSE cardiovascular magnetic resonance using compressed sensing and parallel imaging

BACKGROUND Cine Displacement Encoding with Stimulated Echoes (DENSE) provides accurate quantitative imaging of cardiac mechanics with rapid displacement and strain analysis; however, image acquisition times are relatively long. Compressed sensing (CS) with parallel imaging (PI) can generally provide high-quality images recovered from data sampled below the Nyquist rate. The purposes of the pres...

متن کامل

Temporal 3D Lagrangian strain from 2D slice-followed cine DENSE MRI.

A quantitative analysis of myocardial mechanics is fundamental to the understanding of cardiac function, diagnosis of heart disease and assessment of therapeutic intervention. In clinical practice, most cardiac imaging analyses are performed in 2D because of the limited scan time available. However, the obtained information from a 2D measurement is limited. This study presents a method to obtai...

متن کامل

Accelerated cine DENSE MRI using compressed sensing and parallel imaging

Background Cine DENSE (Displacement Encoding with Stimulated Echoes) provides accurate and high-resolution displacement and strain imaging of the heart; however, image acquisition times are relatively long and, due to properties inherent to stimulated echoes, signal-to-noise ratio (SNR) is relatively low. Accelerated cine DENSE could substantially shorten scan times and/or provide improved spat...

متن کامل

Automated cardiac motion estimation from 3D Cine DENSE MRI

Background 3D cine displacement encoding with stimulated echoes (DENSE) directly encodes tissue displacement into MR phase data, providing a comprehensive 3D view of cardiac motion and strain. Unfortunately, 3D cine DENSE motion analysis presently requires manually delineated anatomy. An automated analysis would reduce interobserver variability, improve measurement throughput, and simplify data...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2015