Assessment of retention force and bone apposition in two differently coated femoral stems after 6 months of loading in a goat model
نویسندگان
چکیده
BACKGROUND Since the introduction of uncemented hip implants, there has been a search for the best surface coating to enhance bone apposition in order to improve retention. The surface coating of the different stems varies between products. The aim was to assess the retention force and bone adaption in two differently coated stems in a weight-bearing goat model. MATERIALS AND METHODS Hydroxyapatite (HA) and electrochemically deposited calcium phosphate (CP; Bonit) on geometrically comparable titanium-based femoral stems were implanted into 12 (CP group) and 35 (HA group) goats. The animal model included physiological loading of the implants for 6 months. The pull-out force of the stems was measured, and bone apposition was microscopically evaluated. RESULTS After exclusion criteria were applied, the number of available goats was 4 in the CP group and 11 in the HA group. The CP-coated stems had significantly lower retention forces compared with the HA-coated ones after 6 months (CP median 47 N, HA median 1,696 N, p = 0.003). Bone sections revealed a lower degree of bone apposition in the CP-coated stems, with more connective tissue in the bone/implant interface compared with the HA group. CONCLUSION In this study, HA had better bone apposition and needed greater pull-out force in loaded implants. The application of CP on the loaded titanium surface to enhance the apposition of bone is questioned.
منابع مشابه
Can bone apposition predict the retention force of a femoral stem? An experimental weight-bearing hip-implant model in goats
BACKGROUND The increasing incidence of prosthesis revision surgery in the Western world has led to an increased focus on the capacity for stem removal. We previously reported on a femoral stem implanted in goats with an approximate 15% reduction in retention force by drilling longitudinally orientated grooves on the side of the stem. In this current study, we aimed to histologically evaluate th...
متن کاملBone density study of the proximal femur after hip arthroplasty with porous-coated implants
Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...
متن کاملBiomechanical and histological evaluation of a hydroxyapatite-coated titanium femoral stem fixed with an intramedullary morsellized bone grafting technique: an animal experiment on goats.
To reconstruct femoral intramedullary bone-stock loss in revision surgery of failed total hip arthro-plasties, morsellized trabecular bone grafts can be used. In 14 goats a noncemented hydroxyapatite-coated titanium stem was fixed within a circumferential construction of bone allografts. After 6 or 12 wk, four goats were used for mechanical tests and three for histology. The stability of the st...
متن کاملChronic Osteomyelitis in the Femoral Midshaft Following Arthroscopic ACL Reconstruction
A 25 year-old man presented with pain, swelling, and intermittent drainage from distal lateral aspect of his left knee three months after undergoing isolated ACL reconstruction with arthroscopic hamstring autograft and endobottom technique. His surgeon at that time tried to eliminate the pathology through arthroscopic wash out in two attempts. However, the pain, edema, and discharge recurred ...
متن کاملRadiologic bone remodeling pattern around DCPD-coated, metaphyseal-loading cementless short stems in elderly patients.
Concerns exist regarding using short stems during total hip arthroplasties performed in elderly patients. For this study, the authors assessed sequential bone remodeling findings in metaphyseal-loading short stems using serial radiography. A total of 100 consecutive primary THAs using short stems were performed in patients with an average age of 78.3 years. The presence and patterns of radioluc...
متن کامل